13.07.2015 Views

VICTRIX 75 - Saint-Roch

VICTRIX 75 - Saint-Roch

VICTRIX 75 - Saint-Roch

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IEThe boiler function modes are given below:0 Stand-by, no operation demand1 Preventilation2 Burner ignition3 Burner lit (system heating)4 Burner lit (domestic hot water)5 Fan check6 Burner off, requested temperature reached7 Pump post-circulation in heating mode8 Pump post-circulation in domestic hot water mode9/b alternating Burner off for one of the blocks listed in the table in:flash l par 3.5 (e.g.: bxx)A 3-way valve checkPARAMETERS Mode Press the MODE key once to enterPARAMETER MODE. In this mode the preset operationalvalues can be changed. The first two figures indicate theparameter number; the last two give the setting value. Tochange the boiler settings proceed as follows:Parameters that can be modified by the user.- Press the MODE key once to enter parameter mode;- using the STEP key select the parameter to be changed;- change the value acting on the + or - keys;- press the STORE key to store the new value;- press MODE to make the new value effective.Parameter Description Lower limit valueUpper limitvalueFactory value1 Domestic hot water setting value 20 °C 70 °C 20 °C0 = excluded2 Domestic hot water functioning mode1 = active2 = excluded + continuous pump03 = active + continuous pump3 Heating function mode0 = excluded1 = active2 = excluded + continuous pump3 = active + continuous pump4 Max. heating delivery temperature 20 °C 85 °C 85 °Cparameter 1: allows domestic hot water temperature to be set if controlledwith NTC probe.parameter 2: allows domestic hot water production to be activated or cut out.With factory settings domestic hot water production is cut out.parameter 3: allows system heating function (Summer) to be cut out, orenabled (Winter). With factory settings system heating is on.1Value set by theuserparameter 4: allows heating delivery temperature to be set. If the externaltemperature probe is connected to the boiler, the electronics automaticallydetermine the ideal system water temperature. This parameter represents themaximum temperature that the system delivery water can reach.INFO Mode Press the MODE key twice to enter INFO mode. In this modethe instantaneous operational values can be displayed and checked, butwithout making changes. The first two figures indicate the step number; thelast two give the setting value.02 40E.g. if these values are shown on the display it means thatthe appliance is operating on heating with a return temperatureof 40 °C.Step Visualisation Value1 Delivery temperature Value in °C2 Return temperature Value in °C34Not active (Domestic temp., if domestic circuit probeis present)Not active (External temperature, if probe is installed)70 (value in °C)-37 (value in °C)6 Delivery temperature setpoint Value in °C7, 8, 9 Temperature gradients (cannot be modified) °C / SE Flame current value µA65

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!