02.04.2013 Views

HEADING PAGE - port of ploce authority * welcome

HEADING PAGE - port of ploce authority * welcome

HEADING PAGE - port of ploce authority * welcome

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ENVIRONMENTAL IMPACT STUDY<br />

Rn: 03-033 CONTAINER TERMINAL PLOCE <strong>PAGE</strong> 2<br />

C.3.1. SEA<br />

During the construction and later the use <strong>of</strong> the terminal, it shall be necessary<br />

to monitor the state <strong>of</strong> the environment for timely discovering <strong>of</strong> possible<br />

unfavourable and undesirable impacts so that additional measures <strong>of</strong><br />

environment protection could be applied. The following environment<br />

monitoring program is proposed:<br />

C.3.1.1. After the construction <strong>of</strong> the facility, the state <strong>of</strong> life communities in the<br />

existing transects should be monitored in the years to come and the obtained<br />

results should be compared with those obtained before the construction.<br />

Regular controls should be carried out every four years for continuous<br />

monitoring <strong>of</strong> the macrobenthonic organisms colonization process and<br />

recovery <strong>of</strong> bottom-dwelling communities in the transect PL-01 I PL-02.<br />

C.3.1.2. Testing the waste water quality at the outlet <strong>of</strong> the treatment plant SZV 1<br />

for oily water coming from the machine maintenance plant shall be<br />

performed four times a year by the laboratory authorized for water quality<br />

testing (Rule on authorized laboratories, OG No. 78/97. The analysis shall<br />

include the determination <strong>of</strong> the following:<br />

• pH,<br />

• total suspended matter,<br />

• chemical oxygen consumption,<br />

• biochemical oxygen consumption,<br />

• overall and mineral oils,<br />

• anionized and unionized detergents.<br />

C.3.1.3 Testing <strong>of</strong> water quality at the outlet <strong>of</strong> the grease trap – sedimentation<br />

chamber SOK 1 and SOK 2, precipitation sewers, shall be performed four<br />

times a year. The analysis shall include the following:<br />

• pH,<br />

• total suspended matter,<br />

• chemical oxygen consumption,<br />

• biochemical oxygen consumption,<br />

• overall and mineral oils.<br />

C.3.1.4 Testing <strong>of</strong> sea water quality shall be carried out on two stations:<br />

• KV 1 within the basin between coast 5 and coast 7<br />

• KV 2 at the basin outlet between the coast 5 and coast 7<br />

two times during summer months in bottom-dwelling and surface sea<br />

layer.<br />

The following indexes <strong>of</strong> water quality should be determined:<br />

• clearness<br />

• temperature<br />

• salinity<br />

• dissolved oxygen<br />

• PH<br />

• mineral oils,<br />

RIJEKAPROJEKT d.o.o.