Figure 7.2.4-2: Adding Transducer Channels<br />

4) Set up the weather station channels<br />

a) Select the blank line at the bottom of the transducer channel list<br />

and click Add.<br />

b) Select Serial Bus (MPB) from the list and click OK.<br />

c) From the list, select the following channels and click OK.<br />

Air pressure Rain current intensity<br />

Air temperature Wind direction average<br />

Relative humidity Wind speed average<br />

d) With the serial channels selected, click Edit.<br />

e) Select the Query and Sample Rates option and click OK.<br />

f) Change the output sample rate to 5 Hz and click OK.<br />

5) Change the ID and/or units of directly-recorded channels.<br />

a) To edit a channel, click on the ID and click Edit.<br />

b) Make the changes in the ID, units (to standard abbreviations),<br />

and invalid data values shown below in the Table 7.2.4 and click<br />

OK.<br />

Note: Only changes from the default settings are shown below.<br />

Make the modifications shown and leave the other fields default.<br />

Table 7.2.4: Changes to Transducer Channel Settings<br />

Interface Original ID New ID<br />

Units (U) or Invalid<br />

Data Output (IDO)<br />

VBM_1 Vertical_Vel VrtVlcty_0 U: m/s<br />

D-38