23.01.2014 Views

IGCAR : Annual Report - Indira Gandhi Centre for Atomic Research

IGCAR : Annual Report - Indira Gandhi Centre for Atomic Research

IGCAR : Annual Report - Indira Gandhi Centre for Atomic Research

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IGC<br />

<strong>Annual</strong> <strong>Report</strong> 2007<br />

these SSCs has to be done by<br />

analysis, testing or from<br />

experience data base. The SSC<br />

list was further segregated<br />

based on qualification<br />

methodology. The document on<br />

safety analysis has been<br />

reviewed by AERB.<br />

The major structures to be<br />

analyzed are the Reactor<br />

Containment Building (RCB),<br />

Steam Generator Building<br />

(SGB), Service Building (SB)<br />

and Control Building (CB). The<br />

major systems to be qualified<br />

by analysis are the primary<br />

sodium system and secondary<br />

sodium system. Consultancy<br />

contract was awarded to M/s<br />

Engineering Mechanics and<br />

<strong>Research</strong> Company (M/s<br />

EMRC), Bangalore, <strong>for</strong> analysis<br />

of RCB, SB & SGB as well as the<br />

secondary sodium system.<br />

EMRC has completed the<br />

modeling and developed floor<br />

response spectra <strong>for</strong> all the<br />

buildings <strong>for</strong> the RBGM. The<br />

modeling of secondary sodium<br />

system has also been<br />

completed by EMRC, and<br />

analysis <strong>for</strong> the RBGM is in<br />

progress. CED, <strong>IGCAR</strong> carried<br />

out a parallel modeling of RCB<br />

<strong>for</strong> checking the EMRC results.<br />

The analysis of CB has been<br />

carried out by CSED, AERB. The<br />

modeling of the primary system<br />

has been completed by NEG,<br />

<strong>IGCAR</strong>, and analysis <strong>for</strong> the<br />

RBGM and floor response<br />

spectra thereof is in progress.<br />

The analysis will include not<br />

only structural integrity, but also<br />

scrammability of the control<br />

rods and pump non-seizure. In<br />

addition, CED, <strong>IGCAR</strong> has<br />

done the modeling of some<br />

support system structures,viz<br />

raw water pump house, cooling<br />

tower and maintenance<br />

building. Analysis of RCB<br />

ventilation ducting is being<br />

done by ROMG.<br />

Ten components have been<br />

identified <strong>for</strong> qualification by<br />

testing on shake-table. For<br />

these, the as-built drawings of<br />

the panels<br />

have been<br />

prepared.<br />

Testing will be<br />

taken up<br />

shortly.<br />

qualified from experience data<br />

base, subject to proper<br />

anchorages. Plant walk-down<br />

was carried out by a team of<br />

engineers & specialists from<br />

NPCIL, AERB & <strong>IGCAR</strong>. Seismic<br />

interactions and anchorages<br />

were studied. The findings of<br />

the walk-down have been<br />

reviewed by the AERB Review<br />

Committee. The walk-down<br />

revealed several areas where<br />

proper anchorages are<br />

required, and areas where<br />

seismic house-keeping is called<br />

<strong>for</strong> to avoid seismic interaction.<br />

Seismic house-keeping has<br />

been completed in zero level of<br />

RCB.<br />

The results of the analysis of<br />

the SSC and of the qualification<br />

tests of components in the<br />

shake table will be submitted to<br />

the Review Committee. Retrofitting<br />

measures, if required,<br />

will be taken up based on the<br />

recommendations of the Review<br />

Committee. The seismic<br />

anchorages will be modified<br />

wherever required, based on<br />

the findings of the plant walkdown<br />

and comments of the<br />

Review Committee. These are<br />

the minimum required <strong>for</strong> plant<br />

relicensing.<br />

Fig.2 Review basis ground motion<br />

Several<br />

components<br />

have been<br />

identified as<br />

g e t t i n g<br />

Finally, system modeling,<br />

capacity assessment of<br />

components and seismic<br />

margin of the plant will be<br />

assessed as a research activity.<br />

6 FAST BREEDER TEST REACTOR

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!