Fig.2 Temperature dependence of<br />
DND signals (SA at 00-00)<br />
<strong>for</strong> signals without background.<br />
Hence these values will prove<br />
useful in deciphering the<br />
location of an actual pin<br />
failure.<br />
The expected rise in signal<br />
over background per cm 2 of<br />
actual fuel failure is given in<br />
Table 2. Considering the<br />
counting statistics of the<br />
detectors used <strong>for</strong> display on<br />
the console, a measurability<br />
criterion of 3 σ background<br />
value implies a failure if the<br />
background counts exceed by<br />
6.7 % on the east and / or 4.8<br />
% on the west under conditions<br />
of sodium inlet temperature<br />
prevailing more than 573K.<br />
The analysis has brought out<br />
that the system is capable of<br />
detecting even fuel defects to<br />
an extent of 0.5 to 1 cm 2 .<br />
Using the measurability criteria<br />
and the pattern of increase of<br />
signal over background, it will<br />
be possible to determine the<br />
size of the clad opening and<br />
localize the defect to the half<br />
sector and the ring in which it is<br />
located.<br />
Fig.4 Response of the DND signal as<br />
function of power (DND SA in 02/04<br />
location)<br />
85m 87 88 135 138 88<br />
K r , K r , K r , X e , C s & R b .<br />
This confirms that cover gas<br />
activity will provide the first<br />
confirmation of an actual pin<br />
failure. General background<br />
Fig.3 Response of the DND signal as<br />
function of power (DND SA in 00/00<br />
location)<br />
The cover gas activity<br />
monitors located in the CRD<br />
circuit and common cover gas<br />
reject circuit also responded<br />
very well. Cover gas samples<br />
collected at higher powers<br />
41<br />
showed the presence of A r ,<br />
Fig.5 Response of the DND signal as<br />
function of power (DND SA in 04/07<br />
location)<br />
Table 1 : Ratios of signals emanating from special SA at 10 MWt<br />
Table 2 : Expected rise in signal (over background) per cm 2 of actual clad failure at 10 MWt<br />
8 FAST BREEDER TEST REACTOR