05.03.2014 Views

addressing uncertainty in oil and natural gas industry greenhouse

addressing uncertainty in oil and natural gas industry greenhouse

addressing uncertainty in oil and natural gas industry greenhouse

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Uncerta<strong>in</strong>ty Estimate for CH 4 <strong>and</strong> CO 2 Emissions from Compressor Starts:<br />

CH4<br />

4 4<br />

= × ×⎜ ⎟<br />

compressor - yr 0.788 tonne mole CH<br />

4<br />

(default EF)<br />

E (11 compressors)<br />

E = 1.81 tonnes CH /yr<br />

CH4<br />

4<br />

0.1620 tonne CH ⎛ 0.80 tonne mole CH (facility)<br />

⎝<br />

⎞<br />

⎠<br />

E<br />

E<br />

CO2<br />

0.1620 tonne CH<br />

4<br />

tonne mole CH4 0.80 tonne mole CH<br />

4<br />

(facility)<br />

= (11 compressors) × × ×<br />

compressor - yr 16.04 tonne CH 0.788 tonne mole CH (default)<br />

4<br />

4 4<br />

tonne mole <strong>gas</strong> 0.12 tonne mole CO2 44.01 tonne CO2<br />

× × × = 0.745 tonnes CO<br />

2<br />

/yr<br />

0.8 tonne mole CH tonne mole <strong>gas</strong> tonne mole CO<br />

0.745 tonne CO<br />

=<br />

⎛1.81 tonne CH<br />

+<br />

21 tonne CO e ⎞<br />

× = 38.7 tonne CO e/yr<br />

⎝<br />

⎠<br />

2 4 2<br />

CO2e ⎜<br />

⎟<br />

2<br />

yr yr tonne CH4<br />

2<br />

Urel ( ) = Urel ( ) + Urel ( ) + Urel ( ) + U<br />

Urel<br />

2 2 2 2<br />

ECO<br />

, E<br />

2 CH4<br />

AF EF Facility mole% Default mole%<br />

( )<br />

2 2 2 2<br />

( )<br />

E ,<br />

0 190 4 5.53 190%, 100% tonnes/yr<br />

CO E<br />

= + + + =+ −<br />

2 CH4<br />

Because the emissions cannot be less than zero, the lower bound <strong>uncerta<strong>in</strong>ty</strong> value for this emission source<br />

is truncated at 100%. Therefore, separate upper <strong>and</strong> lower bound uncerta<strong>in</strong>ties are estimated for the CO 2 e<br />

emissions.<br />

U ( abs) = (U( abs) +U( abs)<br />

2 2<br />

ECO2e ECO2 ECH4<br />

Upper:<br />

2 2<br />

Uabs ( ) = (1.90× 0.745) + (1.90× 21× 1.81) = 72.3 tonnes CO e/yr<br />

ECO2e<br />

2<br />

72.3 tonnes CO e/yr<br />

Urel ( ) = 100% × =+ 187% tonnes CO e/yr<br />

( )<br />

2<br />

ECO2e<br />

2<br />

38.7 tonnes CO2e/yr<br />

U( abs) = U ( abs) + U ( abs)<br />

2 2<br />

ECO 2e ECO E<br />

2 CH4<br />

Lower: abs ( ) ( )<br />

ECO 2e<br />

2 2<br />

U( ) = − 1.00× 0.745 + − 1.00× 21× 1.81 = 38.0 tonnes CO e/yr<br />

rel<br />

38.0 tonnes CO e/y<br />

= × =−<br />

( )<br />

2<br />

U( )<br />

E<br />

100% 98.1% tonnes CO2e/yr<br />

CO2<br />

e<br />

38.7 tonnes CO2e/y<br />

Uncerta<strong>in</strong>ty Estimate for CH 4 <strong>and</strong> CO 2 Emissions from Compressor Blowdowns:<br />

2<br />

E (11 compressors)<br />

CH4<br />

4 4<br />

= × ×⎜ ⎟<br />

compressor - yr 0.788 tonne mole CH<br />

4<br />

(default EF)<br />

E = 0.808 tonnes CH /yr<br />

CH4<br />

4<br />

0.07239 tonne CH ⎛ 0.80 tonne mole CH (facility)<br />

⎝<br />

⎞<br />

⎠<br />

Pilot Version, September 2009 F-30