Replacing the SmartAmp AIB Chassis<br />
8.6 Replacing the SmartAmp AIB Chassis<br />
This procedure provides details on how to replace the SmartAmp AIB chassis on a <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong><br />
i-series robot.<br />
CAUTION: Follow appropriate ESD procedures during the<br />
removal/replacement phases.<br />
Removing the SmartAmp AIB Chassis<br />
1. Switch off the 24VDC input supply to the chassis.<br />
2. Switch off the 200/240VAC input supply to the chassis.<br />
3. Disconnect the 24VDC supply cable from the chassis +24VDC input connector.<br />
See Figure 3-3 on page 34 for locations of connectors.<br />
4. Disconnect the 200/240VAC supply cable from the chassis AC Input connector.<br />
5. Disconnect the AIB XPANEL cable from the XPANEL connector.<br />
6. Disconnect any other cables, which may be connected to the chassis, such as XIO,<br />
RS-232, or any others.<br />
7. Using a 5 mm Allen key, carefully unscrew the chassis securing screw. See Figure<br />
8-2. Note that the screw does not need to be <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pletely removed in order to<br />
remove the chassis, as this screw is captured on the chassis heat sink.<br />
Securing Screw on<br />
SmartAmp AIB<br />
Figure 8-2. Securing Screw on SmartAmp AIB Chassis<br />
8. While holding the chassis heat sink, carefully and slowly lower the chassis down<br />
(see Figure 8-3 on page 106), so that enough access is available to remove the<br />
internal cables. The chassis can be laid flat or placed to the right side of the robot<br />
for better access.<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>i600</s<strong>tr</strong>ong>/i800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 105