Chapter 4 - System Installation<br />
Robot-Mounted Equipment Grounding<br />
The following parts of an <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>i600</s<strong>tr</strong>ong>/i800 robot are not grounded to protective<br />
earth: the Joint 3 quill and the tool flange. If hazardous voltages are present at any<br />
user-supplied robot-mounted equipment or tooling, you must install a ground connection<br />
from that equipment/tooling to the ground point on the robot base. Hazardous voltages<br />
can be considered anything in excess of 30 VAC (42.4 VAC peak) or 60 VDC.<br />
See also Figure 9-4 on page 114 for the grounding point on the tool flange.<br />
DANGER: Failing to ground robot-mounted equipment or<br />
tooling that uses hazardous voltages could lead to injury<br />
or death of a person touching the end-effector when an<br />
elec<strong>tr</strong>ical fault condition exists.<br />
4.10 Installing User-Supplied Safety Equipment<br />
The user is responsible for installing safety barriers to protect personnel from <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ing in<br />
contact with the robot unintentionally. Depending on the design of the workcell, safety<br />
gates, light curtains, and emergency stop devices can be used to create a safe environment.<br />
Read Chapter 2 in this manual for a discussion of safety issues.<br />
Refer to the Section 5.6 on page 59 for information on connecting safety equipment into<br />
the system through the XUSR connector on the AIB XPANEL cable. There is a detailed<br />
section on Emergency Stop Circuits and diagrams on re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended E-Stop<br />
configurations.<br />
48 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>i600</s<strong>tr</strong>ong>/i800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B