Chapter 8 - Maintenance<br />

Groove in robot base<br />

for AIB chassis<br />

placement.<br />

Figure 8-6. Installing AIB Chassis in Robot Base<br />

8. Carefully insert the chassis into the robot base in the groove at the bottom of the<br />

base - see Figure 8-6. Tilt the chassis up and into place against the robot, making<br />

sure that none of the cables get <strong>tr</strong>apped or pinched and that the chassis O-ring is<br />

not damaged during installation.<br />

9. Once the chassis is in place, use a 5 mm Allen key to tighten the chassis securing<br />

screw. See Figure 8-2 on page 105 for details.<br />

10. Connect the 200/240VAC supply cable to the chassis AC Input connector.<br />

11. Connect the AIB XPANEL cable to the XPANEL connector.<br />

12. Connect any other cables, which may be connected to the chassis, such as XIO,<br />

RS-232, or any others.<br />

13. Connect the 24VDC supply cable to the chassis +24VDC input connector.<br />

14. Switch on the 200/240VAC input supply to the chassis.<br />

15. Switch on the 24VDC input supply to the chassis.<br />

16. Once the system has <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pleted booting, test the system for proper operation.<br />

108 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>i600</s<strong>tr</strong>ong>/i800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B