Connecting Customer-Supplied Safety and Power Con<strong>tr</strong>ol Equipment<br />
5.6 Connecting Customer-Supplied Safety and Power Con<strong>tr</strong>ol<br />
Equipment<br />
Connecting Equipment to the System<br />
The connection of the customer-supplied safety and power con<strong>tr</strong>ol equipment to the<br />
system is done through the XUSR and XFP connectors on the AIB XPANEL cable. Refer to<br />
Table 5-7 for the XUSR pin-out explanations. Refer to Table 5-8 on page 60 for the XFP<br />
pin-out explanations. See Figure 5-7 on page 62 for the E-Stop wiring diagram.<br />
Table 5-7. Contacts Provided by the XUSR Connector<br />
Pin<br />
Pairs<br />
Description<br />
Comments<br />
Shorted if<br />
NOT Used<br />
Voltage-Free Contacts Provided by Customer<br />
1, 14<br />
User E-Stop CH 1 (mushroom PB,<br />
safety gates, etc.).<br />
N/C contacts<br />
Yes<br />
2,15<br />
User E-Stop CH 2 (same as pins 1 and<br />
14).<br />
N/C contacts<br />
Yes<br />
3,16 Not supported on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> i-series robot<br />
4,17 Not supported on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> i-series robot<br />
5,18<br />
Muted Safety Gate CH 1 (causes<br />
E-stop in AUTOMATIC mode only).<br />
N/C contacts<br />
Yes<br />
6,19<br />
Muted Safety Gate CH 2 (same as pins<br />
5 and 18).<br />
N/C contacts<br />
Yes<br />
Voltage-Free Contacts provided by <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong><br />
7,20 Not supported on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> i-series robot<br />
8,21 Not supported on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> i-series robot<br />
9,22 Not supported on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> i-series robot<br />
10,23 Not supported on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> i-series robot<br />
11,12,<br />
13,24,25<br />
No connection<br />
Pin 13<br />
XUSR<br />
Pin 1<br />
Pin 25<br />
Pin 14<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>i600</s<strong>tr</strong>ong>/i800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 59