Loupe <br />
The Loupe mode positions a loupe on the SoftProof window. The Touch Console action pane acts like a drawing tablet. <br />
Touch and drag your finger on the touch screen to move the loupe over your image. <br />
Buttons around the edges of the console control the <br />
Loupe’s features: <br />
• Smaller / Bigger – Decrease or increase the size of <br />
the loupe. <br />
• Zoom In / Out – Increase or decrease the <br />
magnification of the loupe. <br />
• Solo Previous / Next Channel – These controls <br />
allow individual Ink Channels of the job to be <br />
viewed within the Loupe, acting as the Show <br />
Channels function. The buttons cycle through each <br />
individual channel then show all channels (default <br />
view). <br />
• Toggle HUD – Toggles the Heads Up Display in the <br />
Loupe window, showing the CMYK dot percentages at the centered cross-‐hair or within the average % box. <br />
• Screened Pixel Readout – Toggles the HUD between cross-‐hair point measurement of ink percentages and a <br />
square for measuring area average dot percentages. The square resizes depending on the zoom % to always <br />
cover an area equal to a full halftone cell at the LPI defined in SoftProof Settings. <br />
Calibrate <br />
The Calibration control screen allows operators to initiate Monitor Calibration and Calchecks for the main SoftProof <br />
display. <br />
• Calibrate – Opens the Displays application and begins the calibration process for the main SoftProof display. <br />
Once calibrated, the monitor ICC profile is automatically saved as the operating system default, replacing the <br />
previous ICC profile. <br />
Note: When calibrating or calchecking, the Spectrophotometer assigned in the Displays application for either <br />
task should be connected and ready for use. If the instrument is different to the assigned one an error will <br />
occur, ceasing the operation. It is recommended to check the appropriate Spectrophotometers have been <br />
assigned before using the Calibrate or Calcheck functions (see Applications > Displays). <br />
• Calcheck – This option will open the Displays application, starting a Calcheck of the softproof display to the <br />
standard patch set in the chart assigned to the current Press. On completion, the Calcheck status of the monitor <br />
is updated with a tick/cross. This button is only available if the currently selected Press Config has an assigned <br />
Calcheck Chart. <br />
Note on Spot Colours: When performing a calcheck of the softproofing display, any special/spot colours included in <br />
the currently loaded job are measured and included in the Calcheck for the purposes of a pass or fail. <br />
View FlipBook <br />
View FlipBook displays a list of available publications that may be opened and viewed using the FlipBook application. <br />
Once a publication is opened, FlipBook controls will appear on the console: <br />
• View 3D, View Calendar, Show Borders and Rendered Thumbnails toggles. <br />
• Decrement/Increment Start Page, Even/Odd Top Page, Read Direction 1-‐>2 / 2