Loupe <br />

The Loupe mode positions a loupe on the SoftProof window. The Touch Console action pane acts like a drawing tablet. <br />

Touch and drag your finger on the touch screen to move the loupe over your image. <br />

Buttons around the edges of the console control the <br />

Loupe’s features: <br />

• Smaller / Bigger – Decrease or increase the size of <br />

the loupe. <br />

• Zoom In / Out – Increase or decrease the <br />

magnification of the loupe. <br />

• Solo Previous / Next Channel – These controls <br />

allow individual Ink Channels of the job to be <br />

viewed within the Loupe, acting as the Show <br />

Channels function. The buttons cycle through each <br />

individual channel then show all channels (default <br />

view). <br />

• Toggle HUD – Toggles the Heads Up Display in the <br />

Loupe window, showing the CMYK dot percentages at the centered cross-­‐hair or within the average % box. <br />

• Screened Pixel Readout – Toggles the HUD between cross-­‐hair point measurement of ink percentages and a <br />

square for measuring area average dot percentages. The square resizes depending on the zoom % to always <br />

cover an area equal to a full halftone cell at the LPI defined in SoftProof Settings. <br />

Calibrate <br />

The Calibration control screen allows operators to initiate Monitor Calibration and Calchecks for the main SoftProof <br />

display. <br />

• Calibrate – Opens the Displays application and begins the calibration process for the main SoftProof display. <br />

Once calibrated, the monitor ICC profile is automatically saved as the operating system default, replacing the <br />

previous ICC profile. <br />

Note: When calibrating or calchecking, the Spectrophotometer assigned in the Displays application for either <br />

task should be connected and ready for use. If the instrument is different to the assigned one an error will <br />

occur, ceasing the operation. It is recommended to check the appropriate Spectrophotometers have been <br />

assigned before using the Calibrate or Calcheck functions (see Applications > Displays). <br />

• Calcheck – This option will open the Displays application, starting a Calcheck of the softproof display to the <br />

standard patch set in the chart assigned to the current Press. On completion, the Calcheck status of the monitor <br />

is updated with a tick/cross. This button is only available if the currently selected Press Config has an assigned <br />

Calcheck Chart. <br />

Note on Spot Colours: When performing a calcheck of the softproofing display, any special/spot colours included in <br />

the currently loaded job are measured and included in the Calcheck for the purposes of a pass or fail. <br />

View FlipBook <br />

View FlipBook displays a list of available publications that may be opened and viewed using the FlipBook application. <br />

Once a publication is opened, FlipBook controls will appear on the console: <br />

• View 3D, View Calendar, Show Borders and Rendered Thumbnails toggles. <br />

• Decrement/Increment Start Page, Even/Odd Top Page, Read Direction 1-­‐>2 / 2