The remainder of the display area shows the current Calcheck status of each connected monitor. Information includes: <br />

• Process Colour/Gray/Paper delta values <br />

• Average/maximum/standard deviation delta values <br />

• Display name (top left) <br />

• Timestamp of the last Calcheck (top right) <br />

• Chart and Instrument used (bottom left) <br />

• Overall Calcheck score (bottom left) <br />

Note: In cases where multiple areas of a screen have been calchecked, the summary will display the worst results from <br />

across all calchecked areas. <br />

Clicking on a Display name under the Calcheck header (e.g., iMac) will allow the user to perform a Calcheck on the <br />

chosen monitor. <br />

The main part of the display area (white box) will show the detail or summary of the Calcheck as it is performed. <br />

The top section above the main area has the following options: <br />

• Δ All – Shows all of the Δ results measured, as defined in the Calcheck Chart. <br />

• Δe – Shows all of the Δe results only. The Δe standard used <br />

(DeltaE/CIE94/CIE2000) is selected in the Calcheck Chart (see Workbench > Calcheck Chart for details). <br />

CIE2000 is a recommended standard to use for display verification. <br />

• ΔH – Shows all of the ΔH results only. <br />

• ΔC – Shows all of the ΔC results only. <br />

• Summary button – Shows Calcheck summary results. <br />

• Detail button – Shows results for each measured patch of the Calcheck Chart. <br />

The lower section of the main display area contains the following: <br />

• Screen Area buttons – These buttons enable the user to look at <br />

results from one of the nine (9) defined areas of the monitor <br />

screen. The buttons are grayed out (cannot be selected) if a <br />

screen area has not been calchecked. Areas that have been checked will enable the button and show whether <br />

the area passed (green) or failed (red) a Calcheck. <br />

• Instrument (offline/online) / Instrument Name – Displays the currently activated instrument. <br />

o<br />

o<br />

Instrument – Select which supported Spectrophotometer is to be used for the Calcheck. <br />

Measurement Type – Select which area of the screen to Calcheck or Calcheck the whole (3x3 grid) <br />

screen. The middle centre of the screen if the default option for standard Calchecks. <br />

History <br />

By clicking on the History header, users can see at a glance the Calcheck summaries for all attached monitors. This is <br />

useful for keeping track of any changes in your monitor’s performance (i.e., drifting). <br />

Information includes: <br />

• Process Colour/Gray/Paper delta values <br />

• Average/maximum/standard deviation delta values <br />

• Display name (top left) <br />

• Timestamp of the last Calcheck (top right) <br />

• Chart and Instrument used (bottom left) <br />

• Overall Calcheck score (bottom left) <br />

These summaries show Calcheck results for the monitor(s) in relation to <br />

the Calcheck Chart used at the time of checking (shown at the bottom left of the summary). The summaries are <br />

independent of the currently assigned SoftProof Default Press / Calcheck Chart although, in most cases they will match <br />

the current Calcheck summaries (see above section). <br />