DI-770 Oscilloscope provides five virtual instruments in one
DI-770 Oscilloscope provides five virtual instruments in one
DI-770 Oscilloscope provides five virtual instruments in one
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>DI</strong>-<strong>770</strong> and WINDAQ/Scope Manual<br />
7. The Voltmeter<br />
If from the <strong>in</strong>put signals only the size is important and not the time <strong>in</strong>formation or frequency comp<strong>one</strong>nts, a voltmeter<br />
is a suitable <strong>in</strong>strument to measure with. The software is equipped with a two channel digital voltmeter. The voltmeter<br />
functions as follows:<br />
• A measurement is performed (m<strong>in</strong>imal 200 samples).<br />
• The measured data is processed, e.g. for calculat<strong>in</strong>g the RMS value or the mean value. Eleven different operations<br />
are available.<br />
• The calculated values are displayed, e.g. add CH1 and CH2 and display on channel <strong>one</strong>. Sixteen different display<br />
methods are available.<br />
For each channel the voltmeter has up to three displays to present the measured and calculated values. The value displayed<br />
<strong>in</strong> a display is fully configurable. Also for each display a bar graph is available, to give a quick overview of<br />
the signal size <strong>in</strong> relation to the <strong>in</strong>put range.<br />
Of all four <strong><strong>in</strong>struments</strong>, the voltmeter has the lowest sett<strong>in</strong>gs priority. This means that if for example the oscilloscope<br />
is active, the record length, pre samples and post samples of the oscilloscope are used <strong>in</strong> the voltmeter. The voltmeter<br />
only uses post samples to perform the calculations. If less than 200 post samples are available, no calculations are<br />
d<strong>one</strong> and a message is displayed. The only sett<strong>in</strong>g that can be changed by the voltmeter when the oscilloscope or<br />
spectrum analyzer is active, is the sample frequency.<br />
The measure system of the voltmeter<br />
The voltmeter takes 200 samples of the <strong>in</strong>put signal with a certa<strong>in</strong> sample frequency. These 200 samples are used to<br />
perform several calculations.<br />
The Voltmeter<br />
45