31.12.2014 Views

DI-770 Oscilloscope provides five virtual instruments in one

DI-770 Oscilloscope provides five virtual instruments in one

DI-770 Oscilloscope provides five virtual instruments in one

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DI</strong>-<strong>770</strong> and WINDAQ/Scope Manual<br />

1. Introduction<br />

Many technicians <strong>in</strong>vestigate electrical signals. Though the measurement may not be electrical, the physical variable<br />

is often converted to an electrical signal, with a special transducer. Common transducers are accelerometers, pressure<br />

probes, current clamps and temperature probes. The advantages of convert<strong>in</strong>g the physical parameters to electrical<br />

signals are large, s<strong>in</strong>ce several <strong><strong>in</strong>struments</strong> for exam<strong>in</strong><strong>in</strong>g electrical signals are available.<br />

The <strong>DI</strong>-<strong>770</strong> is a two channel, 25 or 100 M samples/sec measur<strong>in</strong>g <strong>in</strong>strument. With the accompany<strong>in</strong>g software the<br />

<strong>DI</strong>-<strong>770</strong> can be used as an oscilloscope, a storage oscilloscope, a spectrum analyzer, a true RMS voltmeter, or a data<br />

logger. All <strong><strong>in</strong>struments</strong> measure by sampl<strong>in</strong>g the <strong>in</strong>put signals, digitiz<strong>in</strong>g the values, process them, save them and display<br />

them.<br />

ATTENTION!<br />

Measur<strong>in</strong>g directly on the LINE VOLTAGE can be very dangerous. The OUTSIDE of the BNC CONNECTORS at<br />

the <strong>DI</strong>-<strong>770</strong> are connected with the GROUND of the computer.<br />

Use a good isolation transformer or a differential probe when measur<strong>in</strong>g at the LINE VOLTAGE or at GROUND-ED<br />

POWER SUPPLIES!<br />

In case this has not been considered and the GROUND of the <strong>DI</strong>-<strong>770</strong> is connected to a positive voltage, a short-circuit<br />

current will be flow<strong>in</strong>g. Because of this short-circuit current both the <strong>DI</strong>-<strong>770</strong> and the computer can be damaged.<br />

Safety<br />

Before you start work<strong>in</strong>g with the <strong>DI</strong>-<strong>770</strong>, first read these safety rules.<br />

• Avoid work<strong>in</strong>g al<strong>one</strong>.<br />

• Check the probes / test leads for damages. Do NOT use them if they are damaged.<br />

• Take care when measur<strong>in</strong>g at voltages higher than 25V AC or 60 V DC.<br />

• Measur<strong>in</strong>g directly on the LINE VOLTAGE can be very dangerous. The OUTSIDE of the BNC CONNECTORS<br />

at the <strong>DI</strong>-<strong>770</strong> are connected with the GROUND of the computer.<br />

• Use a good isolation transformer or a differential probe when measur<strong>in</strong>g at the LINE VOLTAGE or at<br />

GROUNDED POWER SUPPLIES!<br />

• In case this has not been considered and the GROUND of the <strong>DI</strong>-<strong>770</strong> is connected to a positive voltage, a shortcircuit<br />

current will be flow<strong>in</strong>g. Because of this short-circuit current both the <strong>DI</strong>-<strong>770</strong> and the computer can be<br />

damaged.<br />

Introduction<br />

1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!