10.07.2015 Views

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Planning</strong> <strong>with</strong> LDA/LDC4.3 Technical data4.3.3 LDA.6.. (5-pole, aluminium)System-specific dataLDA162. LDA262. LDA362. LDA461. LDA462. LDA561. LDA562.N=L N=L N=L PEN=½L N=L N=½L N=LRated current Ie 1)Horizontal/edgewise 2) IP34 Ie A 1100 1250 1600 2000 2000 2500 2500IP54 Ie A 900 1000 1200 1500 1500 1800 1800VerticalIP34 Ie A 950 1100 1250 1700 1700 2100 2100IP54 Ie A 900 1000 1200 1500 1500 1800 1800Horizontal/flat IP31/IP54 Ie A 700 750 1000 1200 1200 1700 1700Impedanceof the conducting paths at Resistance R20 mΩ/m 0.061 0.048 0.048 0.030 0.030 0.023 0.02550 Hz and + 20°C busbartemperatureReactance X20 mΩ/m 0.052 0.043 0.043 0.031 0.031 0.024 0.031Impedance Z20 mΩ/m 0.079 0.064 0.064 0.043 0.043 0.033 0.040of the conducting paths at Resistance R1 mΩ/m 0.072 0.054 0.059 0.036 0.036 0.028 0.02950 Hz and final heating ofbusbarsReactance X1 mΩ/m 0.051 0.043 0.042 0.031 0.031 0.024 0.031Impedance Z1 mΩ/m 0.088 0.069 0.072 0.047 0.047 0.037 0.042of the conducting paths for Resistance RF mΩ/m 0.162 0.108 0.108 0.109 0.109 0.092 0.0845-pole systems (PE) underfault conditions acc. toReactance XF mΩ/m 0.232 0.201 0.201 0.126 0.126 0.134 0.131EN 60439-2 Impedance ZF mΩ/m 0.283 0.228 0.228 0.168 0.168 0.163 0.156of the conducting paths for Resistance RF mΩ/m 0.148 0.108 0.108 0.112 0.067 0.076 0.0565-pole systems (N) under faultconditions acc. to EN 60439-2Reactance XF mΩ/m 0.197 0.173 0.173 0.108 0.108 0.106 0.114Impedance ZF mΩ/m 0.246 0.204 0.204 0.155 0.128 0.130 0.127Zero impedancefor 5-pole systems (PE) acc.R0 mΩ/m 0.310 0.240 0.240 0.250 0.250 0.217 0.213to DIN EN 60909-0/VDE 0102X0 mΩ/m 0.416 0.200 0.200 0.235 0.235 0.202 0.265Z0 mΩ/m 0.517 0.295 0.295 0.343 0.343 0.297 0.340for 5-pole systems (N) acc. toR0 mΩ/m 0.292 0.231 0.231 0.267 0.146 0.181 0.121DIN EN 60909-0/VDE 0102X0 mΩ/m 0.259 0.219 0.219 0.144 0.144 0.128 0.167Z0 mΩ/m 0.392 0.319 0.319 0.303 0.205 0.221 0.206Short-circuit ratingRated short-time <strong>with</strong>stand rms value t = 0.1 s Icw kA 55 70 80 110 110 125 125currentrms value t = 1 s Icw kA 40 55 58 80 80 110 110Rated peak <strong>with</strong>stand current Peak value Ipk kA 121 154 176 242 242 275 275Rated short-time <strong>with</strong>stand rms value t = 0.1 s Icw kA 33 42 48 66 66 75 75current of the 5th conductorrms value t = 1 s Icw kA 24 33 35 48 48 66 66Conductor materialAluminiumNo. of busbars 5 5 5 8 9 8 9Conductor cross section L1, L2, L3 A mm 2 530 706 706 1060 1060 1412 1412N A mm 2 530 706 706 530 1060 6.73 1412PE A mm 2 530 706 706 530 530 706 706Fire loadTrunking unit <strong>with</strong>out tap-offKWh/m 4.16 4.16 4.16 6.14 6.14 6.73 6.73pointper tap-off point KWh 7.80 7.80 7.80 10.80 10.80 10.80 10.80Max. fixing distancesfor conventional mechanicalloadm 6 6 6 5 5 5 51)Dependent upon degree of protection and laying method2)Incl. height rises ≤ 1.3 m<strong>Planning</strong> <strong>with</strong> <strong>SIVACON</strong> 8 <strong>PS</strong>130 <strong>Planning</strong> Manual, 10/2007, A5E01541101-01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!