10.07.2015 Views

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Planning</strong> <strong>with</strong> LDA/LDC4.3 Technical data4.3.9 Tap-off units <strong>with</strong> circuit-breakerSize 1 2 3Circuit-breaker type VL160 VL250 VL400 VL630 VL1250General dataStandards and regulations IEC 60439-1 and -2, DIN EN 60439-1 and -2Rated insulation voltage Uiacc. to IEC 60664-1, VAC 690DIN EN 60664-1VDC 800Overvoltage category/pollution degree acc. toIII/3IEC 60947-1, DIN EN 60947-1Rated operating voltage Ue VAC 400 (690)Rated frequency Hz 50/60Rated current Ie A 50 ... 160 200 ... 250 315 ... 400 580 800 ... 1250Short-circuit ratingAt rated operating voltage Ue V 400Switching capacity of the circuit-breaker H (70 kA) or L (100 kA) L (100 kA)Rated conditional short-circuit current IcckA 70 or 100 100 (35)(values in brackets applicable for 690 V)Current setting of overload release• AE design A 25.2 ... 6340 ... 10080 ... 200100 ... 250126 ... 315160 ... 400252 ... 630 400 ... 1000500 ... 125064 ... 160• DC, EC design A 40 ... 50 160 ... 200 215 ... 315 500 ... 630 -50 ... 6363 ... 8080 ... 100100 ... 125125 ... 160200 ... 250 320 ... 400Ambient temperature• min./max. °C -5 ... +40• max. 24-hour average °C 35EnclosureMaterialSheet steel, zinc-plated/paintedColour Light grey (RAL 7035)Degree of protection• Operation IP54• Mounting procedure IP2XResistance to extreme climates Damp heat, constant, acc. to IEC 60068-2-78Damp heat, cyclic, acc. to IEC 60068-2-30DimensionsSee dimension drawingsMounting positionNo restriction in the case of compliance <strong>with</strong> planning guidelines(cables cannot be fed in from above in the case of vertical installation)ConnectionsBushings• Multi-core cable- Cable sleeves 2 × KT 3 2 x KT 4 4 x KT4- Cable diameters mm 2 14 ... 54 14 ... 68Single-core cable, undrilled aluminium plate, for cable glands 8 × M40 12 x M40 24 x M40- Cable entry from the side Yes Yes YesConductor cross sections (copper)Connection system Direct connection on the device Tags Cable connectionsystemBolted connection 1 x M5 1 x M8 1 x M8 2 x M10 4 x M12L1, L2, L3; N, PEN/PE min. mm 2 1) 1) 1) 1) 4 x (4) x 70max. mm 2 1) 1) 1) 1) 4 x (4) x 2401)In accordance <strong>with</strong> applicable standards<strong>Planning</strong> <strong>with</strong> <strong>SIVACON</strong> 8 <strong>PS</strong><strong>Planning</strong> Manual, 10/2007, A5E01541101-01 139

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!