10.07.2015 Views

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Further information about planning7.3 Functional enduranceAll the information you need about the nature and types of barrier and component, as well asa detailed description of carrier constructions, is contained in the planning authorityapprovals 1)1)There are no general planning authority approvals for various functional endurance classes; please contact the relevant productmanager should you need them.SystemBD2.-160 to 400BD2.-500 to 1250LDA1 to LDA3/LDC2, LDC3(IP34)LDA4 to LDA8/LDC6 toLDC8 (IP34)LX.01, LX.02LXC03, LX.04LX.05LX.06, LX.07LX.08LX.09, LX.10FunctionalenduranceclassDensity d[mm]/PROMATECTplate typeOutside dimensions 1) of thePromat channel(W [mm] x H [mm])Reduction factor 2) according to functionalendurance class and mounting positionHorizontalEdgewise 3)FlatVerticalE60 40/L500 288 x 190 0.75 0.7 0.7E90 50/L500 or LS 308 x 210 0.7 0.65 0.65E60 30/L500 or LS 230 x 280 0.8 0.75 0.75E90 40/L500 250 x 300 0.75 0.7 0.7E120 50/L500 or LS 270 x 320 0.7 0.65 0.65E60 20/L500 260 x 260 057 / 0.58 - 0.56 / 0.54E90 40/L500 300 x 300 0.5 / 0.52 - 0.5 / 0.48E120 60/L500 340 x 340 0.45 / 0.46 - 0.45 / 0.43E90 20/L500 320 x 260 0.57 / 0.57 - 0.44 / 0.48E120 40/L500 360 x 300 0.5 / 0.5 - 0.4 / 0.43E60 30/L500 or LS 250 x 250 0.7 0.7 0.7E90 40/L500 270 x 270 0.65 0.65 0.65E120 50/L500 or LS 290 x 290 0.6 0.6 0.6E60 30/L500 or LS 250 x 280 0.7 0.7 0.7E90 40/L500 270 x 300 0.65 0.65 0.65E120 50/L500 or LS 290 x 320 0.6 0.6 0.6E60 30/L500 or LS 250 x 320 0.7 0.7 0.7E90 40/L500 270 x 340 0.65 0.65 0.65E120 50/L500 or LS 290 x 360 0.6 0.6 0.6E60 30/L500 or LS 250 x 400 0.7 0.7 0.7E90 40/L500 270 x 420 0.65 0.65 0.65E120 50/L500 or LS 290 x 440 0.6 0.6 0.6E90 30/L500 or LS 250 x 550 0.7 0.7 0.7E120 40/L500 270 x 570 0.65 0.65 0.65E90 30/L500 or LS 250 x 710 0.7 0.7 0.7E120 40/L500 270 x 730 0.65 0.65 0.651)Outside dimensions are valid for versions <strong>with</strong> 4 barriers. Dimensions for versions <strong>with</strong> 3 and 2 barriers as well as for versions forLRC are available on request.2)The reduction factors are based on the rated current IE and an ambient temperature of 35°C (24-hour average). In the event oftemperature deviations, reduction factors should be adjusted accordingly. Reduction factors for LRC are available on request.3)Mounting position horizontal edgewise:BD2A/BD2C (trunking unit)LDA/LDC, LXA/LXC, LRC (trunkingconductor)<strong>Planning</strong> <strong>with</strong> <strong>SIVACON</strong> 8 <strong>PS</strong><strong>Planning</strong> Manual, 10/2007, A5E01541101-01 247

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!