10.07.2015 Views

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Planning</strong> principles2.3 Rated currents and short-circuit currents of standard transformers2.3 Rated currents and short-circuit currents of standard transformersRated voltage UrT 400/230 V, 50 Hz 525 V, 50 Hz 690/400 V, 50 HzRated short-circuit4 % 1) 6 % 2) 4 % 1) 6 % 2) 4 % 1) 6 % 2)current value UkrRated powerRated Initial symmetrical Rated Initial symmetrical short-circuit Rated Initial symmetrical shortcircuitcurrent Ir short-circuit current I''k 3) current Ir current I''k 3)current Ircurrent I''k 3)[kVA][A][A][A]50 72 1933 1306 55 1473 995 42 1116 754100 144 3871 2612 110 2950 1990 84 2235 1508160 230 6209 4192 176 4731 3194 133 3585 2420200 288 7749 5239 220 5904 3992 167 4474 3025250 360 9716 6552 275 7402 4992 209 5609 3783315 455 12247 8259 346 9331 6292 262 7071 4768400 578 15506 10492 440 11814 7994 335 8953 6058500 722 19438 12020 550 14810 9158 418 11223 6939630 910 24503 16193 693 18669 12338 525 14147 9349800 1154 -- 20992 880 -- 15994 670 -- 121201000 1444 -- 26224 1100 -- 19980 836 -- 151401250 1805 -- 32791 1375 -- 24984 1046 -- 189321600 2310 -- 39818 1760 -- 30338 1330 -- 229892000 2887 -- 52511 2200 -- 40008 1674 -- 303172500 3608 -- 65547 2749 -- 49941 2090 -- 378443150 4550 -- 82656 3470 -- 62976 2640 -- 477221)ukr = 4 %, standardised to DIN EN 60909-0 / DIN VDE 0102 Part 0 for SrT = 50 ... 630 kVA2)ukr = 6 %, standardised to DIN EN 60909-0 / DIN VDE 0102 Part 0 for SrT = 100 ... 1600 kVA[A]3)I''k Unaffected transformer initial symmetrical short-circuit current in the case of connection to a mains supply <strong>with</strong> unlimitedshort-circuit power taking into account the voltage factor and the correction factor for transformer impedance in accordance <strong>with</strong> DINEN 60909/DIN VDE 0102 Part 0 (July 2002)[A][A]Approximation formulaTransformer rated currentTransformer initial symmetrical short-circuit currentIN [A] = k x SNT [kVA] I''k = IN/Iuk x 100 [A] 400 V: k = 1.45690 V: k = 0.84<strong>Planning</strong> <strong>with</strong> <strong>SIVACON</strong> 8 <strong>PS</strong>30 <strong>Planning</strong> Manual, 10/2007, A5E01541101-01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!