Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GlossaryAThe manufacturers of low-voltage switchgear and controlgear assemblies specify ratedvalues in compliance <strong>with</strong> DIN EN 60439-1. These rated values apply to specified operatingconditions and characterise the suitability of a switchgear assembly. The rated values mustalways be referred to when combining equipment or configuring switchgear and controlgearassemblies.Rated short-time <strong>with</strong>stand current (I cw ) DIN EN 60439-1; 4.3As the rms value of the short-circuit current, the rated short-time <strong>with</strong>stand currentcharacterises the thermal strength of a switchgear and controlgear assembly circuit under atransient load. The rated short-time <strong>with</strong>stand current is normally determined for a duration of1 s; deviating time values must be specified. The rated short-time <strong>with</strong>stand current isspecified for the trunking and/or main busbars of a switchgear and controlgear assembly.Rated peak <strong>with</strong>stand current (I pk ) DIN EN 60439-1; 4.4As the peak value of the impulse current, the rated peak <strong>with</strong>stand current characterises thedynamic strength of a circuit in a switchgear and controlgear assembly. The rated peak<strong>with</strong>stand current is specified for the trunking and/or main busbars of a switchgear andcontrolgear assembly.Rated conditional short-circuit current (I cc ) DIN EN 60439-1; 4.5The conditional rated short-circuit current corresponds to the uninfluenced short-circuitcurrent that a circuit in a switchgear and controlgear assembly, protected by a short-circuitprotective device, can carry <strong>with</strong>out damage (for a certain time). The conditional rated shortcircuitcurrent is therefore specified for tap-off units and/or infeeds <strong>with</strong> circuit-breakers, forexample.Rated impulse <strong>with</strong>stand voltage (U imp ) DIN EN 60947-1; 4.3.1.3This is a measure of the strength of the air paths in the interior of the switchgear in relation totransient overvoltages. Suitable switchgear can be used to ensure that deactivated parts of asystem cannot transmit overvoltages from the line on which they are used.Rated current (I n ) (of a circuit-breaker) DIN EN 60947-2; 4.3.2.3The current that is identical, for the circuit-breaker, to the rated continuous current and theconventional thermal current.➜ Rated uninterrupted current<strong>Planning</strong> <strong>with</strong> <strong>SIVACON</strong> 8 <strong>PS</strong><strong>Planning</strong> Manual, 10/2007, A5E01541101-01 271

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!