10.07.2015 Views

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

Planning with SIVACON 8 PS - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Planning</strong> <strong>with</strong> BD2A/BD2C3.2 System components3.2.8.4 Tap-off units up to 250 ASpecial features● Tap-off units <strong>with</strong> circuit-breaker, fuse switch disconnector and fuse base● Sheet-steel enclosure, hot-dip galvanised and painted, light grey in colour, RAL 7035● Multi-core or single-core cables can be fed in from 3 sides● The cover has to be opened prior to mounting and removing the unit● Anti-rotation feature prevents incorrect mounting.● See technical data for conductor cross sections.NotePlease be aware of the reduced switching capacity when using the tap-off units <strong>with</strong>circuit-breakers at Ue = 690 V.You are not permitted to connect or disconnect the tap-off unit under load.Figure 3-15Tap-off units up to 250 AIe UeDesignTypeA V160 400 <strong>with</strong> 160 A 3-pole circuit-breaker BD2-AK04/LSD-DC(AE)-160-N160 400 <strong>with</strong> 160 A 3-pole circuit-breaker, <strong>with</strong> motor drive BD2-AK04/LSM-DC(AE)-160-N160 400 <strong>with</strong> 160 A 4-pole circuit-breaker BD2-AK04/LSD-EC-160-N160 400 <strong>with</strong> 160 A 4-pole circuit-breaker, <strong>with</strong> motor drive BD2-AK04/LSM-EC-160-N200 400 <strong>with</strong> 200 A 3-pole circuit-breaker BD2-AK04/LSD-DC(AE)-200-N200 400 <strong>with</strong> 200 A 3-pole circuit-breaker, <strong>with</strong> motor drive BD2-AK04/LSM-DC(AE)-160-N200 400 <strong>with</strong> 200 A 4-pole circuit-breaker BD2-AK04/LSD-EC-160-N200 400 <strong>with</strong> 200 A 4-pole circuit-breaker, <strong>with</strong> motor drive BD2-AK04/LSM-EC-160-N250 400 <strong>with</strong> 250 A 3-pole circuit-breaker BD2-AK04/LSD-DC(AE)-250-N250 400 <strong>with</strong> 250 A 3-pole circuit-breaker, <strong>with</strong> motor drive BD2-AK04/LSM-DC(AE)-250-N250 400 <strong>with</strong> 250 A 4-pole circuit-breaker BD2-AK04/LSD-EC-250-N250 400 <strong>with</strong> 250 A 4-pole circuit-breaker, <strong>with</strong> motor drive BD2-AK04/LSM-EC-250-N250 400 <strong>with</strong> 250 A 3-pole fuse switch disconnector BD2-AK04/FS250IEC(BS)-3250 400 <strong>with</strong> 250 A 4-pole fuse switch disconnector BD2-AK04/FS250IEC(BS)-4250 690 <strong>with</strong> 3-pole NH1 fuse base BD2-AK04/SNH1<strong>Planning</strong> <strong>with</strong> <strong>SIVACON</strong> 8 <strong>PS</strong><strong>Planning</strong> Manual, 10/2007, A5E01541101-01 55

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!