7. RADIOGRAPHER’S QUALITY CONTROL TESTSThe tests provided here form a QC programme for the radiographer and in most cases offer a replacement fortests that are in the manufacturer’s programme. It is not necessary to perform both sets of tests. This programmedoes not include maintenance or calibration procedures. Maintenance and calibration activities should be performedby the appropriate individual according to the manufacturer’s instructions.A brief description of the methodology to be undertaken when performing the radiographer’s QC tests isprovided in this section (Table 4). The tests do not necessarily have to be performed in the order in which theyappear in this publication. The preferred order will depend on various factors relating to the mammography facilityas well as the preferences of the individual performing the testing, always keeping in mind that the results of onetest may affect the execution of others. Data collection sheets are found in Annex I and are available in electronicformat, along with other information relevant to testing of digital mammography, on the IAEA web site at:http://<strong>human</strong><strong>health</strong>.<strong>iaea</strong>.orgTABLE 4. RADIOGRAPHER’S QUALITY CONTROL TESTSTest Priority a Tolerances or recommended levelsDaily testsMonitor inspection, cleaning and viewing conditions D b See Section 7.1.1.4Digital mammography equipment daily checklist E See Section 7.1.2.5Daily flat field phantom image D See Section 7.1.3.5Visual inspection for artefacts (CR systems only) E See Section 7.1.4.4Laser printer sensitometry E c See Section 7.1.5.4Image plate erasure (CR systems only) E d See Section 7.1.6.3Weekly testsMonitor QC E See Section 7.2.1.4Viewbox cleanliness E See Section 7.2.2.4Weekly QC test object and full field artefacts E See Section 7.2.3.4Image quality with breast mimicking phantom D See Section 7.2.4.4Monthly testsSafety and function checks of examination room andequipmentE See Section 7.3.1.4Full field artefacts E See Section 7.3.2.4Laser printer artefacts E e See Section 7.3.3.4Quarterly testsPrinted image quality f E See Section 7.4.1.4Repeat image analysis E See Section 7.4.2.6Spatial resolution test(CR and scanning systems only)E See Section 7.4.3.339

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!