Direct to analysers method:<br />

o <strong>The</strong> subject sits at rest for a minimum <strong>of</strong> 5 minutes.<br />

. Each subject inhales to total lung capacity then performs a slow vital capacity manoeuvre to<br />

residual volume over 30-60 seconds.<br />

. 5 exhalations are made consecutively at 3-minute intervals.<br />

o Nose clips are worn 5 seconds before the exhalation, and taken <strong>of</strong>f between measurements.<br />

. Measurements <strong>of</strong> NO, mouth pressure and COz are made.<br />

. Mouth pressure is standardised to 4 mmHg by a fixed restriction.<br />

. <strong>The</strong> sampling rate <strong>of</strong> the combined analysers was 44Omls/min.<br />

T-piece sampling system to analysers method:<br />

o <strong>The</strong> subject sits at rest for a minimum <strong>of</strong> 5 minutes.<br />

. Each subject inhales to total lung capacity then performs a slow vital capacity manoeuvre to<br />

residual volume over 30-60 seconds.<br />

o 5 exhalations are made consecutively at 3-minute intervals.<br />

o Nose clips are worn 5 seconds before the exhalation, and taken <strong>of</strong>f between measurements.<br />

o Measurements <strong>of</strong> NO, mouth pressure and CO2, and flow are made.<br />

. Mouth pressure is standardised to 4 mmHg by a fixed restriction.<br />

. Flow in the t-piece was standardised by having the subject exhale at a constant rate <strong>of</strong><br />

221mllmin. <strong>The</strong> subjects controlled their expiratory flow rates voluntarily observing the<br />

rotameter bobbin level <strong>of</strong> the pneumotachograph for visual feedback.<br />

o <strong>The</strong> sampling rate <strong>of</strong> the combined analysers including the flow was 665mls/min<br />

Figure 6.3: Schematic diagrams <strong>of</strong> the two different types <strong>of</strong> connections: direct and t-piece<br />

measurements<br />

Direct:<br />

O<br />

0<br />