13.07.2015 Views

TRITON - Web Security Help, Version 7.7 - Websense

TRITON - Web Security Help, Version 7.7 - Websense

TRITON - Web Security Help, Version 7.7 - Websense

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TroubleshootingFiltering issues<strong>TRITON</strong> - <strong>Web</strong> <strong>Security</strong> <strong>Help</strong> | <strong>Web</strong> <strong>Security</strong> Solutions | <strong>Version</strong> <strong>7.7</strong>.x Filtering service is not running, page 456 User Service is not available, page 457 Sites are incorrectly categorized as Information Technology, page 458 Keywords are not being blocked, page 458 Custom or limited access filter URLs are not filtered as expected, page 459 An FTP request is not blocked as expected, page 459 <strong>Web</strong>sense software is not applying user or group policies, page 459 Remote users are not filtered by correct policy, page 460Filtering service is not running<strong>TRITON</strong> - <strong>Web</strong> <strong>Security</strong> <strong>Help</strong> | <strong>Web</strong> <strong>Security</strong> Solutions | <strong>Version</strong> <strong>7.7</strong>.xWhen Filtering Service is not running, Internet requests cannot be filtered and logged.Filtering Service may stop running if:There is insufficient disk space on the Filtering Service machine (see Insufficientdisk space on the Filtering Service machine, page 453).A Master Database download failed due to lack of disk space (see The MasterDatabase does not download, page 450).The websense.ini file is missing or corrupted.You stop the service (after creating custom block pages, for example) and do notrestart it.Filtering Service may also appear to have stopped if you restarted multiple <strong>Web</strong>senseservices, and they were not started in the correct order. When you restart multipleservices, remember to start the Policy Database, Policy Broker, and Policy Serverbefore starting other <strong>Web</strong>sense services.To troubleshoot these problems:Verify that there is at least 3 GB of free disk space on the Filtering Servicemachine. You may need to remove unused files or add additional capacity.Navigate to the <strong>Web</strong>sense bin directory (C:\Program Files or Program Files(x86)\<strong>Web</strong>sense\<strong>Web</strong> <strong>Security</strong>\bin or /opt/<strong>Web</strong>sense/bin/, by default), andconfirm that you can open websense.ini in a text editor. If this file has beencorrupted, replace it with a backup file.Check the Windows Event Viewer or websense.log file for error messages fromFiltering Service (see Troubleshooting tips and tools, page 523).Log off of <strong>TRITON</strong> - <strong>Web</strong> <strong>Security</strong>, restart Policy Server, and then restartFiltering Service (see Stopping and starting <strong>Web</strong>sense services, page 385).456 <strong>Web</strong>sense <strong>Web</strong> <strong>Security</strong> Solutions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!