SolarEdge
SolarEdge Installation Guide â MAN-01-00057-2.3
SolarEdge Installation Guide â MAN-01-00057-2.3
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Chapter 2: Installing the Power Optimizers<br />
Chapter 2: Installing the Power Optimizers<br />
Safety<br />
The following notes and warnings apply when installing the power optimizers. modules:<br />
WARNING!<br />
When modifying an existing installation, turn OFF the inverter ON/OFF switch and the AC<br />
circuit breaker on the main AC distribution panel.<br />
WARNING!<br />
Input and output connectors are not watertight until mated. Open connectors should be<br />
mated to each other or plugged with appropriate watertight caps.<br />
CAUTION!<br />
This unit must be operated according to the operating specifications in this document.<br />
CAUTION!<br />
All PV modules must be connected to a power optimizer.<br />
CAUTION!<br />
Cutting the power optimizer input or output cable connector is prohibited and will void the<br />
warranty.<br />
CAUTION!<br />
Power optimizers are IP65/NEMA4 rated. Choose a mounting location where optimizers<br />
will not be submerged in water.<br />
CAUTION!<br />
If you intend to mount the optimizers directly to the module or module frame, first consult<br />
the module manufacturer for guidance regarding the mounting location and the impact, if<br />
any, on module warranty. Drilling holes in the module frame should be done according to<br />
the module manufacturer instructions.<br />
12<br />
<strong>SolarEdge</strong>-Installation Guide MAN-01-00057-3.1