SolarEdge
SolarEdge Installation Guide â MAN-01-00057-2.3
SolarEdge Installation Guide â MAN-01-00057-2.3
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Telemetry Status<br />
Telemetry Status<br />
This window displays the last power optimizer telemetry received. The display changes as<br />
each power optimizer sends its telemetry.<br />
In order to verify proper installation, the installer may view the Telemetry window for some<br />
time in order to observe the power optimizers' report process.<br />
M o d u l e : 0 0 0 C 1 E D 9 - 0 3<br />
E n e r g y [ W h ] : 0 V d c _ O<br />
[ V ] : 4 0 . 5 V d c _ I<br />
[ V ] : 2 9 . 5<br />
• Module#: Power optimizer serial number<br />
• Energy: power optimizer energy<br />
• Vdc_O: Power optimizer output voltage<br />
• Vdc_I: Power optimizer input voltage (module voltage)<br />
ID Status<br />
This window displays the inverter software version and the country to which the inverter is<br />
configured.<br />
I D : # # # # # # # # # #<br />
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4<br />
C P U : 0 0 0 3 . 1 4 x x<br />
C o u n t r y : E S P<br />
• ID: The inverter ID.<br />
• DSP 1/2: The DSP digital control board firmware version<br />
• CPU: The communication board firmware version<br />
• Country: the current country setting<br />
Server Communication Status<br />
S e r v e r : L A N < S _ O K ><br />
S t a t u s : < O K ><br />
x x x x x x x x<br />
< E R R O R M E S S A G E ><br />
• Server: The method of connection to the <strong>SolarEdge</strong> monitoring portal.<br />
• S_OK: The connection to the <strong>SolarEdge</strong> monitoring portal is successful (should appear<br />
only if the inverter is connected to the server).<br />
50<br />
<strong>SolarEdge</strong>-Installation Guide MAN-01-00057-3.1