Appendix B: Technical Specifications<br />

Appendix B: Technical Specifications<br />

SE2200 SE3000 SE3500 SE4000 SE4000-16A SE5000 SE6000 Unit<br />

Output<br />

Rated AC power output 2200 3000 3500 4000 4000 5000 1 6000 W<br />

Maximum AC power output 2200 3000 3500 4000 4000 5000 1 6000 W<br />

AC output voltage (nominal) 220/230/240 Vac<br />

AC output voltage range 184 – 264.5 Vac<br />

AC frequency(nominal) 50/60 ±5 Hz<br />

Maximum continuous output current 12 16.5 2 19.5 2 22 16 27 27 A<br />

Max. continuous overcurrent<br />

protection<br />

12 16.5 2 19.5 2 22 16 27 27 A<br />

Residual current detector/ Residual<br />

current step detector<br />

300/30 mA<br />

Inrush current AC (Peak/Duration) 2.8/20<br />

Aac<br />

(rms)<br />

/ ms<br />

1 4985W when the country is set to Australia;4600W when the country is set to Germany or the Czech Republic.<br />

2 16A when the country is set to Denmark, Portugal, UK, or Poland. For other countries, contact <strong>SolarEdge</strong>.<br />

<strong>SolarEdge</strong>-Installation Guide MAN-01-00057-3.1<br />