Components<br />

Component group: Ignition<br />

purge_time Data type: num<br />

The time (in seconds) it takes to fill gas lines and the welding gun with protective<br />

gas, so-called “gas purging”.<br />

If the first weld instruction contains the argument \On (flying start), the gas flow<br />

is activated at the specified gas purge time before the programmed position is<br />

reached.<br />

If the positioning time to the start position of the weld is shorter than the gas<br />

purge time, or if the \On argument is not used, the robot waits in the weld start<br />

position until the gas purge time has expired.<br />

preflow_time Data type: num<br />

The time (in seconds) it takes to preflow the weld object with protective gas, socalled<br />

“gas preflowing”.<br />

The robot is stationary in position during this time before the arc is ignited.<br />

ign_sched (ignition schedule) Data type: num<br />

The identity (expressed as a number) of a weld program in connected welding<br />

equipment. It is sent to the welding equipment to be used during ignition of the<br />

arc.<br />

See System Parameter Arc Welding - Equipment - schedport_type.<br />

ign_voltage Data type: num<br />

The welding voltage (in volts) during ignition of the arc.<br />

The value specified is scaled and sent to the corresponding analog output, in<br />

accordance with the setting in the system parameters for analog signals.<br />

ign_wirefeed Data type: num<br />

The feed speed of the weld electrode during ignition of the arc.<br />

The unit is defined in the system parameter Arc Welding - Units - unit_feed and,<br />

as a rule, is m/minute or inches per minute.<br />

The value specified is scaled and sent to the corresponding analog output, in<br />

accordance with the setting in the system parameters for analog signals.<br />

ign_volt_adj (ignition voltage adjustment) Data type: num<br />

The welding voltage adjustment during ignition of the arc.<br />

<strong>RAPID</strong> Reference Manual 13-seamdata-3