System Module SWUSRC<br />

Contents<br />

Data<br />

The system module SWUSRC contains data and routines aimed at customising the<br />

behaviour of the SpotWare Plus application. They are used and executed commonly by<br />

all <strong>RAPID</strong> tasks of SpotWare.<br />

NB. Any change of routines in SWUSRC requires the following three steps to<br />

affect the application (see also System Parameters Multitasking):<br />

- save to ramdisk<br />

- touch the multitasking configuration<br />

- WARM START to affect the application<br />

The names are predefined and used internally when a SpotL instruction is used. They<br />

must therefore not be changed.<br />

If standard SpotWare is used, see the system module SWUSER.<br />

The following global data are predefined:<br />

Name Declaration Description<br />

sw_weld_counter PERS num<br />

sw_weld_counter := 0<br />

sw_gp_timeout PERS num<br />

sw_gp_timeout := 2<br />

sw_wr_timeout PERS num<br />

sw_wr_timeout := 2<br />

sw_go_timeout PERS num<br />

sw_go_timeout := 2<br />

sw_prog_max PERS num<br />

sw_prog_max := 63<br />

Counter for welded spots. The counter<br />

is automatically incremented in<br />

the SpotL instruction.<br />

Gun pressure timeout [s]<br />

Weld ready timeout [s]<br />

Gun open timeout [s]<br />

Max. value for prog_no in spotdata.<br />

<strong>RAPID</strong> Reference Manual 14-SWUSRC-1