spotdata Spot weld data<br />

Description<br />

Components<br />

Spotdata is used to define the parameters that control a weld timer and weld gun for<br />

welding a certain spot.<br />

Spotdata is referred to spot weld instructions and contains data which controls the<br />

welding in the actual instruction.<br />

Spotdata has the following structure:<br />

- Program number for the program in the weld timer to be used.<br />

- Electrode tip to be activated (in case of a double gun).<br />

- Desired gun pressure (if connected).<br />

- Weld timer number (if more than one).<br />

prog_no (program number) Data type: num<br />

Defines the internal program in the weld timer to be used for the welding.<br />

The allowed range is 0..sw_prog_max (defined in the system module<br />

SWUSER).<br />

tip_no (electrode pair number) Data type: num<br />

Defines the electrode pair to be activated. The following alternatives are<br />

available:<br />

1: Electrode pair 1<br />

2: Electrode pair 2<br />

12: Electrode pairs 1 and 2. Both pairs are closing at the same time.<br />

The welding is done in sequence, pair 1 first and pair 2 second.<br />

Then, both electrodes are opening together.<br />

21: Electrode pairs 2 and 1. Both pairs are closing at the same time.<br />

The welding is done in sequence, pair 2 first and pair 1 second.<br />

Then, both electrodes are opening together.<br />

For guns with only one pair of electrodes the value shall be 1.<br />