See also Predefined Data and Programs.<br />

Instruction parameter error<br />

The error occurs when SpotL is called with faulty parameters. The program stops.<br />

The parameter must be changed and the current instruction restarted from the<br />

beginning.<br />

Supervision before welding<br />

The supervisions in sw_preweld_sup are in progress. See Predefined Data and<br />

Programs - System Module SWUSER or SWUSRC.<br />

Weld error<br />

A weld error occurs if the ready signal from the weld timer has not been set to a certain<br />

time (sw_wr_timeout). SpotL can be configured to automatically reweld a certain<br />

number of times before the error is displayed and the execution stops, waiting for a<br />

manual action.<br />

- The start signal is set low.<br />

- The gun opens.<br />

- The process error signal is set high.<br />

- The following manual choices are available:<br />

Automatic mode: Service / Reweld<br />

Manual mode: Service / Skip / Reweld (see the dialog box in Figure 2).<br />

Program Waiting for Data!<br />

Weld_ready timeout<br />

Service Skip Reweld<br />

Figure 2 Dialog box for weld error.<br />