Specifications<br />

INSTALLATION<br />

General Specifications<br />

Frequency Range<br />

1.7 to 180 Hz<br />

You must make certain that the motor and<br />

associated equipment are capable of<br />

operating safely, and that protective guards<br />

are in place, before you operate your drive<br />

above 60 Hz.<br />

Input Line Conditions<br />

¥ Three phase 240 VAC, three phase 480<br />

VAC, or single phase 240 VAC (±10 %).<br />

¥ Input line impedance - 1% to 5%. You must<br />

purchase a 1% input line reactor if you<br />

calculate or measure input line<br />

impedance less than 1%.<br />

¥ Line Distortion - The harmonic voltage<br />

distortion of the input power line should be<br />

limited to 10% or less including distortion<br />

caused by the drive(s). (See IEEE<br />

Standard 519.)<br />

¥ Input phase voltage unbalance less than 3%<br />

(per IEEE Standard 446).<br />

¥ Single phase input protection - drive will<br />

safely run on single phase until input current<br />

rating of the drive is exceeded. The output<br />

current rating must be derated by 50%<br />

for all drives except the 2 Hp, 240 VAC<br />

unit (AF93AG0B002D) when single phase<br />

240 V power is supplied. The 2 Hp, 240<br />

VAC unit is fully rated for single phase or<br />

three phase application.<br />

AF93/IS903 Instruction Manual<br />

2-36<br />

! Caution<br />

It is your responsibility to check your installation<br />

to make sure it meets the conditions stated in<br />

these specifications before you install your<br />

Adjustable Frequency Drive. Operation of the<br />

drive outside of these specifications will void<br />

your warranty.<br />

¥ Drive insensitive to line phase sequence.<br />

¥ Suitable for use on a circuit capable of<br />

delivering not more than 65K RMS<br />

symmetrical amperes, 480 volts maximum.<br />

Input Line Transients<br />

¥ Drive protected and operational for line<br />

transients to ANSI C62.41 (formerly IEEE 587)<br />

and IEC 801.<br />

¥ Drive protected (but may trip) for severe or<br />

prolonged transients per IEEE 446.<br />

Operator Interface<br />

The AF93/IS903 operator interface consists of:<br />

¥ An LCD display (two rows of 16 characters per<br />

row) and keypad.<br />

¥ Operator can display operating conditions,<br />

parameter settings, or English language<br />

diagnostic messages on the LCD.<br />

¥ Operator can change the settings of a predefined<br />

list of parameters.<br />

¥ Operator can issue Start, Stop, Forward, and<br />

Reverse commands and change speeds using<br />

the keypad. Keypad can also be set for<br />

remote Start and speed change.