Checking DC Bus Voltage<br />

TROUBLESHOOTING<br />

Step 1. Set a digital volt meter to read DC volts,<br />

and use the 0 to 1000V scale.<br />

Step 2. Connect the digital volt meter between<br />

the ÒAÓ and ÒBÓ terminals of the capacitor<br />

assembly as shown in Fig. 5-1.<br />

Step 3. Monitor the bus voltage until it reaches<br />

zero volts DC.<br />

AF93/IS903 Instruction Manual<br />

5-6<br />

! Danger High Voltage<br />

Internal parts of the drive are at line voltage<br />

when AC power is connected to input terminals.<br />

This voltage is extremely dangerous and can<br />

cause death or serious injury. When the supply<br />

is disconnected from the input terminal block, it<br />

will take up to 10 minutes before the DC bus<br />

capacitors are discharged to a safe voltage.<br />

To ensure the voltage is safe, monitor the<br />

capacitor discharge with a digital voltmeter<br />

connected between the ÒAÓ and ÒBÓ terminals on<br />

the capacitor assembly as described. Do not<br />

work on the drive until the capacitors have<br />

completely discharged. Do not attempt to<br />

discharge the capacitors by short circuiting the<br />

bus.