Safety<br />
Rotating mechanical equipment can cause<br />
serious personal injury and property damage<br />
unless you handle them carefully, especially<br />
when the equipment is operating:<br />
¥ Never wear loose fitting clothing, such as ties<br />
and scarves, when you operate rotating<br />
mechanical equipment.<br />
¥ Always wear safety glasses when you<br />
operate rotating mechanical equipment.<br />
¥ Stand clear, and make sure all hands and<br />
feet are clear, of rotating mechanical<br />
equipment before you start the Adjustable<br />
Frequency Drive.<br />
¥ Refer to OSHA rules and regulations,<br />
paragraph 1910.219 for the use of guards on<br />
mechanical power transmission devices.<br />
AF93/IS903 Instruction Manual<br />
S-4<br />
Warning<br />
Caution<br />
AF93/IS903 Adjustable Frequency Drives<br />
contain components and sub-assemblies that<br />
are sensitive to electrostatic discharge. Static<br />
control precautions are required when installing,<br />
testing, servicing, or repairing your Adjustable<br />
Frequency Drive. Component damage may<br />
result if you ignore electrostatic discharge<br />
control procedures. Observe the following<br />
precautions when you are working with electrical<br />
subassemblies:<br />
¥ Before opening the enclosure, discharge<br />
static electricity from your body by touching a<br />
grounded metal object.<br />
¥ When installing the equipment, connect the<br />
equipment ground conductor as soon as<br />
possible.<br />
¥ Keep your hands and tools away from the<br />
electronic circuitry as much as possible. Nonconductive<br />
materials such as paper, plastic<br />
and Styrofoam must be kept away from the<br />
electronic circuitry. Do not use tape in the<br />
equipment enclosure. Pulling tape from a roll<br />
generates a high static charge.<br />
¥ Printed circuit boards must be repaired by<br />
<strong>Cutler</strong>-<strong>Hammer</strong> technicians. Field service of<br />
printed circuit boards inside your AF93/IS903<br />
is not possible without the proper software or<br />
diagnostic tools.