AF93/IS903 Parameter Descriptions<br />

USING THE PARAMETERS<br />

Jump Speeds 1 through 3<br />

Specifications<br />

Parameter Number: 34 to 36<br />

Mnemonic: JUMP SPEED x LO<br />

where ÒxÓ is a value of 1 to 3<br />

Range of Adjustment: Minimum Speed to<br />

Maximum Speed<br />

Run Locked?: No<br />

Factory Setting: 0<br />

These parameters set jump speeds which are<br />

used to avoid operating at speeds that create<br />

problems with mechanical resonance. The jump<br />

speeds, combined with Jump Width (parameter<br />

37), create frequency windows. The drive can<br />

accelerate or decelerate smoothly through the<br />

windows, but will not stop at any frequency within<br />

a window. Jump frequency windows are<br />

illustrated in the graph shown below.<br />

Jump Width<br />

Specifications<br />

Parameter Number: 37<br />

Mnemonic: JUMP WIDTH<br />

Range of Adjustment: 0 to Maximum Speed<br />

Run Locked?: No<br />

Factory Setting: 0<br />

This parameter allows you to define the band<br />

width of frequencies around each jump speed<br />

where the drive will not operate continuously.<br />

AF93/IS903 Instruction Manual<br />

4-22<br />

hz<br />

133<br />

106<br />

79<br />

53<br />

26<br />

0<br />

0<br />

Jump<br />

Width<br />

Jump Speed 1<br />

Jump Speed 2<br />

Jump<br />

Speed 3<br />

26 53 79 106 133 hz<br />

ETN-JUMP SPD<br />

Typical Jump Speed Graph<br />

DC Injection Braking<br />

Specifications<br />

Parameter Number: 38<br />

Mnemonic: DC BRAKE TIME<br />

Range of Adjustment: 0 to 16 sec<br />

Run Locked?: No<br />

Factory Setting: 0.0 sec<br />

This parameter defines how long in seconds that<br />

DC injection braking lasts. When DC current is<br />

injected into the windings of an induction motor,<br />

the motor acts as a brake. Approximately 20%<br />

braking torque is injected for the period of time<br />

set by this parameter when the motor speed<br />

drops below 5 Hz.<br />

Relay 1 and<br />

Relay 2<br />

Specifications<br />

Parameter Number: 39 and 40<br />

Mnemonic: RELAY 1 or RELAY 2<br />

Range of Adjustment: One of the following eight<br />

functions can be selected<br />

for each of the two relays:<br />

ÒREADYÓ, ÒRUNÓ,<br />

ÒREVERSEÓ, ÒKEYPADÓ,<br />

ÒAT SPEEDÓ, ÒZERO<br />

SPEEDÓ, ÒLOAD LIMITÓ,<br />

ÒOVERLOAD WARNINGÓ<br />

Run Locked?: Yes<br />

Factory Setting: Relay 1: ÒRUNÓ<br />

Relay 2: ÒAT SPEEDÓ<br />

RELAY 1 defines the relay function when drive is<br />

in RUN mode. RELAY 2 defines the relay<br />

function when drive is Òat speedÓ.