Cutler-Hammer - Eaton Canada
Cutler-Hammer - Eaton Canada
Cutler-Hammer - Eaton Canada
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
AF93/IS903 Parameter List<br />
USING THE PARAMETERS<br />
Customer<br />
Setting<br />
Factory<br />
Setting<br />
Notes<br />
Range of Adjustment<br />
Parameter<br />
(LCD Display)<br />
AF93/IS903 Instruction Manual<br />
4-8<br />
ÒAT SPEEDÓ<br />
Run Locked<br />
(Following are the range<br />
of outputs possible)<br />
Relay 2<br />
(RELAY 2)<br />
40<br />
Drive not in FAULT mode.<br />
ÒREADYÓ<br />
Drive in RUN mode.<br />
ÒRUNÓ<br />
Drive in REVERSE mode.<br />
ÒREVERSEÓ<br />
Relay 2 will change state when<br />
the drive is in KEYPAD mode.<br />
ÒKEYPADÓ<br />
Drive at speed setpoint.<br />
ÒAT SPEEDÓ<br />
Drive in STOP mode and<br />
stopped. Motor may be<br />
spinning if in Coast Stop<br />
profile.<br />
ÒZERO SPEEDÓ<br />
Asserted when the drive is in<br />
load limit.<br />
ÒLOAD LIMITÓ<br />
Asserted when motor is at risk<br />
of tripping on thermal overload.<br />
ÒOVERLOAD<br />
WARNINGÓ