AF93/IS903 Parameter List<br />
USING THE PARAMETERS<br />
Customer<br />
Setting<br />
Factory<br />
Setting<br />
Notes<br />
Range of Adjustment<br />
Parameter<br />
(LCD Display)<br />
0<br />
Ò0Ó equals Auto Restart is<br />
disabled. Restart counter is<br />
reset every 60 minutes.<br />
Run Locked<br />
0 to 255<br />
Number of Restart<br />
Attempts Before<br />
Lockout<br />
(RESTART<br />
ATTEMPTS)<br />
43<br />
5<br />
Run Locked<br />
1.0 to 300.0 seconds<br />
Time Between Restart<br />
Attempts<br />
(RESTART DELAY)<br />
44<br />
ÒCOASTÓ or<br />
ÒRAMPÓ<br />
Stop Profile<br />
(STOP PROFILE)<br />
45<br />
0 to 100<br />
Load Inertia<br />
(LOAD INERTIA)<br />
46<br />
ÒDISABLEÓ or<br />
ÒENABLEÓ<br />
Forward/Reverse<br />
(REVERSE DIR.)<br />
47<br />
ÒDISABLEÓ or<br />
ÒENABLEÓ<br />
Enable Select Key<br />
(SELECT KEY)<br />
AF93/IS903 Instruction Manual<br />
4-10<br />
ÒRAMPÓ<br />
20<br />
Run Locked<br />
ÒENABLEÓ<br />
Run Locked<br />
ÒENABLEÓ<br />
Run Locked<br />
48<br />
ÒDISABLEÓ<br />
ÒENABLEÓ or<br />
ÒDISABLEÓ<br />
Efficiency Optimization<br />
(EFFICIENCY OPT)<br />
49<br />
ÒDISABLEÓ<br />
If set to ENABLE, drive will<br />
restart after waiting the period<br />
of time set in Parameter 44<br />
(RESTART DELAY) if power is<br />
applied in REMOTE mode with<br />
Start and Stop/Run Enable<br />
inputs closed.<br />
ÒENABLEÓ or<br />
ÒDISABLEÓ<br />
Power Up Restart<br />
(POWER UP<br />
RESTART)<br />
50<br />
If set to DISABLE, drive will<br />
require a transition on the Start<br />
or Stop/Run Enable input to<br />
restart.