AF93/IS903 Parameter Descriptions<br />

USING THE PARAMETERS<br />

Minimum Potentiometer<br />

Reference<br />

Specifications<br />

Parameter Number: 6<br />

Mnemonic: MIN POT REF<br />

Range of Adjustment: 0 to 100%<br />

Run Locked?: Yes<br />

Factory Setting: 10%<br />

Minimum and maximum analog potentiometer<br />

values are used to scale potentiometer inputs<br />

(setpoint and feedback) if the drive is in the<br />

REMOTE mode. See Remote Function<br />

(parameter 23) for details. Minimum<br />

Potentiometer Reference defines the minimum<br />

value in terms of percent of full range. If the full<br />

range is used, the following are the values for<br />

direct and inverse acting control:<br />

0% equals min. speed at 0V (direct acting)<br />

100% equals min. speed at 10V (inverse acting)<br />

Maximum Potentiometer<br />

Reference<br />

Specifications<br />

Parameter Number: 7<br />

Mnemonic: MAX POT REF<br />

Range of Adjustment: 0 to 100%<br />

Run Locked?: Yes<br />

Factory Setting: 90%<br />

This parameter defines the maximum value in<br />

terms of percent of full range. If the full range is<br />

used, the following are the values for direct and<br />

inverse acting control:<br />

100% equals max. speed at 10V (direct acting)<br />

0% equals max. speed at 0V (inverse acting)<br />

AF93/IS903 Instruction Manual<br />

4-14<br />

Minimum Analog Reference<br />

Specifications<br />

Parameter Number: 8<br />

Mnemonic: MIN ANALOG REF<br />

Range of Adjustment: 0 to 100%<br />

Run Locked?: Yes<br />

Factory Setting: 0%<br />

Minimum and maximum analog reference values<br />

are used to scale analog inputs (setpoint and<br />

feedback) if the drive is in the REMOTE mode.<br />

See Remote Function (parameter 23) for details.<br />

Minimum Analog Reference defines the minimum<br />

value in terms of percent of full range. If the full<br />

range is used, the following are the values for<br />

direct and inverse acting control:<br />

0% equals min. speed at 4 mA (direct acting)<br />

100% equals min. speed at 20 mA (inverse acting)<br />

Maximum Analog<br />

Reference<br />

Specifications<br />

Parameter Number: 9<br />

Mnemonic: MAX ANALOG REF<br />

Range of Adjustment: 0 to 100%<br />

Run Locked?: Yes<br />

Factory Setting: 100%<br />

This parameter defines the maximum value in<br />

terms of percent of full range. If the full range is<br />

used, the following are the values for direct and<br />

inverse acting control:<br />

100% equals max. speed at 20 mA (direct<br />

acting)<br />

0% equals max. speed at 4 mA (inverse acting)