Advanced Building Skins<br />

For the frame, the limits "soft" and "rigid" were investig<strong>at</strong>ed. Here "soft" means free glass edges (x, yand<br />

z-direction), "rigid" means simply supported edges of both glass panes in z-direction.<br />

The interlayer is modelled with a Young's modulus of 1.0 N/mm² and a Poisson's r<strong>at</strong>io of ν = 0.499.<br />

The temper<strong>at</strong>ure difference T was increased progressively up to 20°C (e.g. rain cooling). Figure 8<br />

shows the stress distribution of the finite-element calcul<strong>at</strong>ions which takes into account geometrical<br />

nonlinearity.<br />

Figure 8: Principle tensile stresses on the outer surface of the upper glass pane with symmetrical (left) and<br />

asymmetrical (right) temper<strong>at</strong>ure distribution and soft frame<br />

The maximum principal tensile stresses occur under symmetrical load ΔT,1 <strong>at</strong> the outer surfaces. With<br />

the asymmetrical load T,2 these are loc<strong>at</strong>ed on the outer surface of the upper glass pane (Figure 9).<br />

Figure 9: Thermal expansion (ɛtherm) and tensile stresses (σmax) for symmetrical (left) and asymmetrical (right)<br />

temper<strong>at</strong>ure distribution<br />

Figure 10 shows an almost linear rel<strong>at</strong>ion between temper<strong>at</strong>ure difference and the glass stresses. The<br />

small differences arise from the geometrically nonlinear analysis. Furthermore, it indic<strong>at</strong>es th<strong>at</strong> the<br />

consider<strong>at</strong>ion of the load case temper<strong>at</strong>ure can be quite relevant for structural design, especially if the<br />

capacity of the modules is already reached with other loads.<br />