PROTECTIONS OF THE UNIT ITSELF (<strong>8055</strong>)<br />

"Axes" and "Inputs/Outputs" modules.<br />

All the digital inputs and outputs have galvanic isolation via optocouplers between the <strong>CNC</strong> circuitry<br />

and the outside.<br />

They are protected by an external fast fuse (F) of 3.15 A 250V against overvoltage of the external power<br />

supply (over 33 Vdc) and against reverse connection of the power supply.<br />

Monitor.<br />

The type of protection fuse depends on the type of monitor. See identification label of the unit itself.<br />

Central Unit.<br />

It has a 4 A 250V external fast fuse (F).<br />

PROTECTIONS OF THE UNIT ITSELF (<strong>8055</strong>I)<br />

OUT IN<br />

X7<br />

X9<br />

X2<br />

X10<br />

X3<br />

X11<br />

X4<br />

Inputs-Outputs.<br />

All the digital inputs and outputs have galvanic isolation via optocouplers between the <strong>CNC</strong> circuitry<br />

and the outside.<br />

X12<br />

X5<br />

X1<br />

X8<br />

+24V<br />

0V<br />

X13<br />

X6<br />

FUSIBLE FUSE<br />

Safety conditions<br />

<strong>CNC</strong> <strong>8055</strong><br />

<strong>CNC</strong> <strong>8055</strong>i<br />

·13·