2.7.4 Part centering with / without a probe (level 3)<br />
Part centering with / without a probe is in level 3 of the tool calibration mode.<br />
Use the following icons to access the screen for part centering with or without a probe.<br />
i<br />
Part centering with a probe.<br />
Part centering without a probe.<br />
If the tabletop probe has not been configured or the probing cycles have been hidden (bit 1 of g.m.p.<br />
COCYF1=1), the <strong>manual</strong> part centering cycle will appear at level 2 of the tool calibration mode. In this<br />
case, part centering with a probe will not be displayed.<br />
PART CENTERING WITH A PROBE<br />
This calibration level requires the purchase of the right software <strong>option</strong>s purchased and the use of<br />
a table-top probe.<br />
Using a digital probe, this cycle calculates the real center coordinates, surface coordinate and<br />
inclination angle of a rectangular part or the real center and surface coordinates of a circular part.<br />
Rectangular or circular part centering with a probe.<br />
Data to be entered<br />
Icon for selecting the axis and the direction (X+, X-, Y+, Y-) of the first probing movement.<br />
Icon to select part surface measuring.<br />
Icon to select the type of part to be centered (rectangular or circular).<br />
L, H: Part lengths (length and width if rectangular, diameter if circular).<br />
Z: Distance for the probe to go up in Z for probing movements over the part.<br />
Ds: Part approaching distance in part searching probing movements. If not programmed, it<br />
takes the approach distance left by the operator.<br />
Dr: Withdrawal distance, after the part searching probing movement for measuring.<br />
X: X coordinate of the probe position where the first probing move will start. If not<br />
programmed, it will assume the current X position of the probe.<br />
Y: Y coordinate of the probe position where the first probing move will start. If not<br />
programmed, it will assume the current Y position of the probe.<br />
Z: Z coordinate of the probe position where the first probing move will start. If not<br />
programmed, it will assume the current Z position of the probe.<br />
2.<br />