2.<br />

OPERATING IN JOG MODE<br />

Tool calibration<br />

<strong>CNC</strong> <strong>8055</strong><br />

<strong>CNC</strong> <strong>8055</strong>i<br />

·<strong>MC</strong>· OPTION<br />

SOFT: V01.3X<br />

·58·<br />

Tool calibration<br />

<strong>Operating</strong> <strong>manual</strong><br />

The right window shows the tool dimensions and the lower left window shows the necessary data<br />

to calibrate it.<br />

To access the calibration window, (lower left window) and, thus calibrate the tool, the tool must be<br />

selected on the machine. If it is not, press the [T] key, key in the desired number of the tool to be<br />

calibrated and press [START].<br />

Select the lower left window with the [] [] [] [] keys Enter the Z coordinate of the part to be<br />

used in the calibration and press [ENTER].<br />

Tool calibration (only measuring the length).<br />

1. Approach the tool to the part and touch it with it.<br />

2. Then, press the keystroke sequence [Z] [ENTER].<br />

The tool has been calibrated. The <strong>CNC</strong> assigns the corresponding length (L) to it and resets the<br />

K offset value to 0. The tool radius (R) must be entered <strong>manual</strong>ly.<br />

To calibrate another tool:<br />

1. Select it on the machine.<br />

2. Approach the tool to the part and touch it with it.<br />

3. Then, press the keystroke sequence [Z] [ENTER].<br />

Modifying the tool data while executing a program<br />

It is possible to modifying the tool values (dimensions and geometry) without interrupting the<br />

execution of a program.<br />

To do that, press the tool calibration key. The <strong>CNC</strong> will show the tool calibration screen<br />

with all the data for the active tool and it will allow modifying its data or of any other tool.<br />

To exit this screen, press [ESC].