a. Americans with Disabilities Act - ADA<br />

b. Uniform Federal Accessibility Standards - UFAS<br />

c. ANSI A117.1 Standard for Accessible and Usable Building s and Facilities<br />

C. Certifications:<br />

1. Fire-rated doors and frames shall bear labels by Underwriters Laboratories, Inc., Warnock Hersey<br />

International, or other nationally recognized organizations acceptable to authority having<br />

jurisdiction. Provide fire-rated doors with a label permanently attached to either hinge stile or to top<br />

rail, showing testing agency approval for classification scheduled.<br />

2. Door assemblies shall bear fire-rating labels indicating following:<br />

a. Hourly fire rating<br />

b. Temperature rise developed on unexposed surface after 30 minutes of exposure<br />

c. Letter “S” to designate smoke-resistance<br />

d. Name and address of listee<br />

e. Model number of type<br />

f. Symbol, serial or issue number of listing agency<br />

3. Tops of doors shall bear a label from manufacturer indicating door construction, face veneer<br />

species, cut, grade, and finishing information.<br />

1.06 DELIVERY, STORAGE, AND HANDLING<br />

A. Packing, Shipping, Handling, and Unloading:<br />

1. Doors shall be individually wrapped in poly bags. Break seals on-site to permit ventilation.<br />

2. Clearly label each door with opening number where door is scheduled for installation. Use<br />

removable, temporary labels or mark on door surface that will be concealed from view after<br />

installation.<br />

a. Coordinate door identification with shop drawing designations.<br />

3. Handle doors in a manner to prevent damage to exposed surfaces in compliance with WDMA I.S.1-<br />

A, Section G-20 Care and Installation at Job Site.<br />

4. Do not drag doors across one another.<br />

B. Storage and Protection:<br />

1. Store doors in a protected, dry area at least 6” (150 mm) off floor.<br />

2. Stack units so that water cannot accumulate on or within materials, using shims to provide<br />

drainage and air circulation.<br />

3. Protect doors from direct exposure to sunlight.<br />

4. Avoid subjecting doors to extreme heat, dryness, or moisture.<br />

5. Doors that have been scratched, or otherwise damaged shall be removed from Site.<br />

1.07 PROJECT CONDITIONS<br />

A. Environmental Requirements:<br />

1. Spaces shall be ready to receive wood doors with temperature and humidity controlled to avoid<br />

damage by excessive changes in atmospheric conditions. Temperature and humidity shall be<br />

stabilized in installation areas at approximate level that will prevail in building when occupied.<br />

Relative humidity shall be not less than 30% or more than 60%.<br />

1.08 SPECIAL WARRANTY<br />

A. Provide manufacturer’s written warranty covering cost to repair or replacement of defective materials or<br />

workmanship for a periods as indicated below from Date of Substantial Completion. Warranty shall cover<br />

defects that render doors unacceptable or unfit for ordinary, recommended use, including, but not limited to<br />

delaminating, warping, and core telegraphing through face.<br />

1. Stile and Rail Wood Doors: Five years<br />

2. Solid Core Flush Slab Wood Doors: Life of Original Installation<br />

WOOD DOORS 08 14 00-4