SECTION 06 10 00 - ROUGH CARPENTRY<br />

PART 1 - GENERAL<br />

1.01 SUMMARY<br />

A. Work Included: Rough carpentry as shown on the drawings.<br />

1.02 QUALITY ASSURANCE<br />

A. Grade Marks:<br />

1. Lumber grade mark stamps shall contain following:<br />

a. Symbol of grading agency certified by Board of Review of American Lumber Standards<br />

Committee<br />

b. Mill number or name<br />

c. Grade of lumber<br />

d. Species or species grouping or combination designation<br />

e. Rules under which graded were applicable<br />

f. Condition of seasoning at time of manufacture<br />

i) S-GRN: Unseasoned<br />

ii) S-DRY: Maximum Moisture Content 19%<br />

iii) MC-15 or KD: Maximum Moisture Content 15%<br />

PART 2 - PRODUCTS<br />

2.01 MATERIALS<br />

A. Lumber: PS-20; graded in accordance with established Grading Rules.<br />

1. Maximum Moisture Content: 19%<br />

2. Lumber shall be S4S dressed, unless otherwise indicated.<br />

B. Plywood: PS 1; bearing grade trademark of American Plywood Association.<br />

C. Treated Wood:<br />

1. Fire Retardant Treatment:<br />

a. Provide materials which comply with UL surface burning characteristics, Type A in<br />

accordance with requirements of AWPA Standards C20 for lumber and C27 for plywood<br />

and kiln dried after treatment KDAT as a minimum.<br />

b. Fire retardant chemical shall be free of halogens, sulfates, ammonium phosphate, and<br />

formaldehyde and shall be registered for use as a wood preservative by U.S.<br />

Environmental Protection Agency.<br />

c. Flame spread rating shall be not more than 25, when tested by ASTM E84 with no<br />

increase in flame spread and significant progressive combustion upon continuation of<br />

test for an additional 20 minutes.<br />

d. Fire retardant lumber and plywood shall have an Underwriter's Laboratory stamp FR-S.<br />

e. Lumber shall be kiln dried to a maximum moisture content of 19% after treatment, and<br />

plywood redried to a maximum moisture content of 15% after treatment.<br />

f. Fire retardant treated wood shall have an equilibrium moisture content of not more than<br />

25% when tested in accordance with ASTM D3201 at 95% relative humidity.<br />

2. Preservative Treatment:<br />

a. Provide materials which comply with requirements of AWPA LP-2 as a minimum.<br />