AHB ComponentsConfigurable optionsThe EBM has a fixed functionality and is not programmable. There are, however,compilation-time or simulation-time options, using Verilog parameters. Table 3-11 liststhe configurable options.Parameter Type Default value DescriptionTable 3-11 Configurable optionsEBMenable Boolean '1' (True) When set to 0 (false), this parameter prevents the master fromgenerating any transfersEBMreadAddr 8-bit vector 0xD0 Bits [31:24] of the base address for the read burst, dword alignedEBMwriteAddr 8-bit vector 0xC4 Bits [31:24] of the base address for the write transfers, dwordalignedEBMinitCount 10-bit vector 0x004 The number of IDLE transactions between burstsEndiannessThe EBM supports little-endian mode only.3.11.2 Signal descriptionsThe EBM uses only <strong>AMBA</strong> signals. For a description of the <strong>AMBA</strong> signals, see <strong>AMBA</strong>signals on page 1-3.3-46 Copyright © 2003, 2007 <strong>ARM</strong> Limited. All rights reserved. <strong>ARM</strong> DDI 0243C