Closed Impression<br />
Method<br />
System Components<br />
The system components for the closed<br />
impression method are consistently<br />
color-coded. A fixing screw for impression<br />
post, impression cap, and bite registration<br />
cap are supplied along with the<br />
impression post. A screwdriver - extra<br />
short, short, long - is required. The screw<br />
must be hand-tightened both in the<br />
implant and in the lab analog.<br />
All transfer system and bite registration<br />
components are single-use<br />
items!<br />
For precision reasons, they may not<br />
be reused.<br />
Screwdrivers,<br />
extra short, short, long<br />
The fixing screw extends<br />
about 2 mm above the<br />
inserted impression post.<br />
Overview of color-coded impression posts and impression caps<br />
Transfer System<br />
Closed Impression Method<br />
Impression post,<br />
Lab analog,<br />
Fixing screw for<br />
impression post<br />
After fasten the screw, it<br />
sits flush with the upper<br />
edge (4-5 turns)<br />
Bite registration cap<br />
Impression cap<br />