<strong>Surgery</strong> Manual<br />
SCREW-LINE Insertion<br />
Implant Bed Preparation<br />
Overview of the implant bed preparation.<br />
Note: implant bed preparation is identical<br />
for SCREW-LINE Implants with<br />
Promote ® and Promote ® plus surfaces.<br />
• Punch-mark the desired implant position<br />
with the internally irrigated Ø<br />
2.3 mm round bur.<br />
• Deep drill along the implant axial line<br />
with the internally irrigated Ø 2.0 mm<br />
pilot drill.<br />
• Check with Ø 1.7-2.8 / 2.0 mm paralleling<br />
pin with depth marks.<br />
• Pre-drill with the internally irrigated Ø<br />
1.7-2.8 mm pre-drill.<br />
• Check with the Ø 1.7-2.8 / 2.0 mm<br />
paralleling pin with depth marks.<br />
• Shape with internally irrigated form<br />
drill.<br />
• Probe the implant bed hole for its<br />
bony end.<br />
• Cortical bone drilling (for bone quality<br />
D1).<br />
• Thread cutting with SCREW-LINE tap<br />
(for bone quality D1 and D2)<br />
42<br />
Optional for all<br />
diameters<br />
1.0 mm<br />
0.4 mm<br />
Promote ® plus<br />
Promote ®<br />
0.4 mm<br />
The indication range and implant bed<br />
preparation of the SCREW-LINE Implant<br />
are identical for Promote ® and Promote ®<br />
plus surfaces.<br />
Drilling Sequence<br />
Ø 3.3 mm<br />
Ø 3.8 mm<br />
Ø 4.3 mm<br />
Ø 5.0 mm<br />
Ø 6.0 mm<br />
Round bur<br />
Ø 2.3 mm<br />
Round bur<br />
Ø 2.3 mm<br />
Round bur<br />
Ø 2.3 mm<br />
Round bur<br />
Ø 2.3 mm<br />
Round bur<br />
Ø 2.3 mm<br />
Pilot drill<br />
Ø 2.0 mm<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
Depth Stop<br />
Depth Stop<br />
Depth Stop<br />
Depth Stop<br />
Depth Stop<br />
* If the bone quality is D1 or D2, use of the tap (thread cutter) is recommended for SCREW-LINE<br />
Implants.<br />
Paralleling pin<br />
Paralleling pin<br />
Paralleling pin<br />
Paralleling pin<br />
Paralleling pin<br />
Pre-drill<br />
Ø 1.7 –<br />
2.8 mm<br />
rpm 800 800 600<br />
Pilot drill<br />
Ø 2.0 mm<br />
Pilot drill<br />
Ø 2.0 mm<br />
Pilot drill<br />
Ø 2.0 mm<br />
Pilot drill<br />
Ø 2.0 mm<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
Pre-drill<br />
Ø 1.7 –<br />
2.8 mm<br />
rpm 800 800 600<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
Pre-drill<br />
Ø 1.7 –<br />
2.8 mm<br />
rpm 800 800 600<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
Pre-drill<br />
Ø 1.7 –<br />
2.8 mm<br />
rpm 800 800 600<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm<br />
Pre-drill<br />
Ø 1.7 –<br />
2.8 mm<br />
rpm 800 800 600<br />
16 mm<br />
13 mm<br />
11 mm<br />
9 mm