Exeter Residences/888 Boylston<br />
\\Mabos\projects\09916.00\docs\Permits\DPIR\Text\DPIR Chapter 5<br />
Environmental.docx<br />
from the beginning of April to the beginning of March. Thus the Spring Equinox will<br />
move from Standard Time to Daylight Savings Time and the sun will be somewhat<br />
lower at 9am and noon and somewhat higher at 3pm then what this study portrays.<br />
The study scenarios include:<br />
155-feet Zoning Height; and<br />
Proposed Program.<br />
155-Feet Zoning Height – Exeter Residences & 888<br />
Boylston<br />
March 21, 9am EST: Figure 5-35 shows effects are restricted to the Prudential Center<br />
Arcade roof, the south face of the Mandarin Oriental <strong>Boston</strong>, a small number of north<br />
facing offices of the Prudential Tower, the northwest corner of Saks Fifth Avenue<br />
roof, and a minor width of the Gloucester building. The range of glare varies from a<br />
minor to average level of intensity.<br />
March 21, 12 noon EST: Figure 5-35 identifies a small area of glare striking the<br />
Prudential Center Arcade roof, the Shaw’s Supermarket loading dock roof and a<br />
portion of the southern Exeter Street sidewalk. The glare experienced by pedestrians<br />
and/or cyclists on the sidewalk will be of minor intensity and shifting<br />
simultaneously with time. It is important to note that the Prudential Center Arcade<br />
roof provides glazing on the windows to minimize or alleviate any discomfort<br />
received by pedestrians from rooftop glare.<br />
March 21, 3pm EST: As indicated by Figure 5-35, shafts of reflected sunlight strike<br />
the Hynes Convention Center roof, the Prudential Center Arcade roof, the Lord &<br />
Taylor roof, and a small section of the southwest façade of the Fairfield building.<br />
Furthermore, a thin shaft of glare will affect the eastern sidewalk of Exeter Street at<br />
this date and hour. The level of intensity during this study time varies from minor to<br />
average with the majority being on average.<br />
March 21, 6pm EST: Figure 5-35 depicts sunlight reflected onto the Hynes<br />
Convention Center roof and the Lord & Taylor roof with a minor level of intensity.<br />
Several thin shafts of glare will affect building rooftops on the northern side of<br />
Boylston Street and the southern portion of Newbury Street, ranging from minor to<br />
moderately intense levels of glare. Furthermore, a small collection of moderately<br />
intense glare will hit the western façade of the Mandarin Oriental <strong>Boston</strong> during this<br />
time and date.<br />
DRAFT - Environmental Protection 5-34