Exeter Residences /888 Boylston<br />

Energy & Atmosphere<br />

Materials & Resources<br />

Indoor Environmental Quality<br />

\\Mabos\projects\09916.00\docs\Permits\DPIR\Text\DPIR Chapter 7 Sustainable<br />

Design.docx<br />

Overall energy use of the core and shell shall be reduced below ASHRAE 90.1-2004<br />

standards which are also a betterment to the standard of the Massachusetts Energy<br />

Code reductions. A number of energy conservation technologies along with<br />

enhanced commissioning services and ongoing measurement and verification of both<br />

the base building and future tenant systems shall be implemented to optimize<br />

building performance when occupied. No CFC (chlorofluorocarbon) based<br />

refrigerants will be used to reduce ozone depletion in the atmosphere. To support<br />

the generation of grid-source renewable energy, renewable trading certificates may<br />

be purchased for the core and shell electricity supply.<br />

A demolition and construction waste management plan shall be implemented during<br />

construction of the <strong>Project</strong> to divert the majority of waste material from landfills.<br />

Recycling shall be strongly encouraged by the tenants with convenient areas for<br />

collection and storage. Construction materials for the core and shell shall contain<br />

significant percentages of recycled content. Every effort shall be used to use local<br />

materials or materials manufactured regionally.<br />

The comfort and well-being of the occupants shall be paramount in regard to airquality<br />

and access to day-light and outside views. Finishes, adhesives, and sealants<br />

for the core and shell shall be selected for low VOC (volatile organic compounds)<br />

content to minimize the environmental impacts of off-gassing. The HVAC system<br />

will be designed and constructed to deliver an increased mix of fresh air to support<br />

the core and tenant spaces. During construction, an IAQ (indoor air quality)<br />

Management Plan will be implemented to protect mechanical systems from<br />

contamination.<br />

Sustainable Design & Practices 7-9