SINAMICS S120 drive system<br />

Line Modules and line-side components<br />

Smart Line Modules in chassis format<br />

© <strong>Siemens</strong> AG <strong>2013</strong><br />

■ Overview<br />

■ Design<br />

3<br />

The Smart Line Modules have the following interfaces as<br />

standard:<br />

• 1 power connection<br />

• 1 connection for the 24 V DC electronics power supply<br />

• 1 DC link connection (DCPA, DCNA) for connecting a<br />

Braking Module<br />

• 3 DRIVE-CLiQ sockets<br />

• 1 PE (protective earth) connection (2 connections for frame<br />

sizes HX and JX)<br />

The status of the Smart Line Modules is indicated via two<br />

multi-color LEDs.<br />

The scope of supply of the Smart Line Modules includes:<br />

• DRIVE-CLiQ cable to connect to a CU320-2 or<br />

SIMOTION D4x5-2 Control Unit or Controller Extension<br />

CX32-2<br />

• DRIVE-CLiQ cable for connection between the Control Unit<br />

and first Motor Module (type dependent)<br />

Smart Line Modules are non-regulated feed/feedback units with<br />

100 % continuous regenerative feedback power. The regenerative<br />

feedback capability of the modules can be deactivated by<br />

means of parameterization.<br />

Smart Line Modules are designed for connection to grounded<br />

TN/TT and non-grounded IT systems.<br />

The DC link is pre-charged via integrated pre-charging resistors.<br />

The associated line reactor is absolutely essential for<br />

operating a Smart Line Module.<br />