Catalog PM 21 2013 - Siemens Industry, Inc.
Catalog PM 21 2013 - Siemens Industry, Inc.
Catalog PM 21 2013 - Siemens Industry, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
© <strong>Siemens</strong> AG <strong>2013</strong><br />
SINAMICS S120 drive system<br />
Line Modules and line-side components<br />
Smart Line Module in booksize compact format<br />
■ Technical specifications (continued)<br />
■ Selection and ordering data<br />
Line voltage<br />
380 ... 480 V 3 AC<br />
• Internal air cooling<br />
cold plate cooling<br />
Feed/feedback power<br />
• Rated power P rated<br />
- At 380 V 3 AC<br />
- At 460 V 3 AC 3)<br />
• For S6 duty (40 %) P S6<br />
• P max<br />
DC link current<br />
• At 600 V DC<br />
• For S6 duty (40 %)<br />
•Maximum<br />
Input current<br />
• Rated current<br />
at 380 V 3 AC<br />
• For S6 duty (40 %)<br />
•Maximum<br />
Current requirement<br />
24 V DC electronics power supply,<br />
max.<br />
Current carrying capacity<br />
• 24 V DC busbars<br />
• DC link busbars<br />
DC link capacitance<br />
• Smart Line Module<br />
• Drive line-up, max.<br />
Power loss 1)<br />
• With internal air cooling<br />
• With cold plate cooling, int./ext.<br />
• Thermal resistance R th<br />
Cooling air requirement<br />
Sound pressure level L pA (1 m)<br />
Line connection<br />
U1, V1, W1<br />
Smart Line Module<br />
in booksize compact format<br />
6SL3430-6TE<strong>21</strong>-6AA1<br />
16 kW<br />
(18 HP)<br />
<strong>21</strong> kW<br />
35 kW<br />
27 A<br />
35 A<br />
59 A<br />
26 A<br />
35 A<br />
59 A<br />
1.1 A<br />
20 A<br />
100 A<br />
705 μF<br />
6000 μF<br />
0.19 kW<br />
0.06/0.13 kW<br />
0.13 K/W<br />
0.016 m 3 /s (0.57 ft 3 /s)<br />
< 60 dB<br />
Screw-type terminals (X1)<br />
• Conductor cross-section, max. 2.5 … 10 mm 2<br />
Shield connection<br />
Cable shield connection plate<br />
integrated into the connector<br />
Description<br />
Line voltage 380 ... 480 V 3 AC<br />
Smart Line Module<br />
in booksize compact format<br />
Internal air cooling<br />
Cold plate cooling<br />
Rated power<br />
• 16 kW (18 HP)<br />
Accessories<br />
DC link rectifier adapter<br />
For direct infeed of DC link voltage<br />
Screw-type terminals 0.5 ... 10 mm 2<br />
For Line Modules and Motor Modules<br />
in booksize format with a width of<br />
50 mm (1.97 in) or 100 mm (3.94 in)<br />
DC link adapters<br />
(2 units)<br />
For multi-tier configuration<br />
Screw-type terminals 35 ... 95 mm 2<br />
For all Line Modules and<br />
Motor Modules in booksize format<br />
Accessories for re-ordering<br />
24 V terminal adapter<br />
For all Line Modules and<br />
Motor Modules in booksize format<br />
24 V jumper<br />
For connection of the 24 V busbars<br />
(for booksize format)<br />
Warning labels<br />
in 30 languages<br />
This set of foreign language warning<br />
labels can be placed on top of the<br />
standard German or English signs.<br />
A set of labels is supplied with the units.<br />
One sign in each of the following<br />
languages is provided in each set:<br />
BG, CN, CZ, DE, DK, EE, ES, FI, FR,<br />
GB, GR, HU, IE, IS, IT, JP, KR, LT, LV,<br />
MT, NL, NO, PL, PT, RO, RU, SE, SI,<br />
SK, TR<br />
SINAMICS/SINUMERIK/SIMOTION<br />
dust-proof blanking plugs<br />
(50 units)<br />
For DRIVE-CLiQ port<br />
Order No.<br />
6SL3430-6TE<strong>21</strong>-6AA1<br />
6SL3162-2BD00-0AA0<br />
6SL3162-2BM01-0AA0<br />
6SL3162-2AA00-0AA0<br />
6SL3162-2AA01-0AA0<br />
6SL3166-3AB00-0AA0<br />
6SL3066-4CA00-0AA0<br />
3<br />
PE connection<br />
M5 screw<br />
Cable length, max.<br />
(total of all motor power cables<br />
and DC link) 2)<br />
• Shielded<br />
350 m (1148 ft)<br />
• Unshielded<br />
560 m (1837 ft)<br />
Degree of protection<br />
IP20<br />
Dimensions<br />
• Width<br />
100 mm (3.94 in)<br />
•Height<br />
270 mm (10.6 in)<br />
•Depth<br />
226 mm (8.90 in)<br />
Weight, approx.<br />
5.3 kg (12 lb)<br />
1) Power loss of Smart Line Module at rated power including losses of<br />
24 V DC electronic power supply.<br />
2) Max. cable lengths in conjunction with Voltage Clamping Module,<br />
see derating characteristics.<br />
3) Nominal HP ratings are provided for ease of assigning components only.<br />
The Line Module outputs are dependent on the Motor Module loading and<br />
are to be dimensioned accordingly.<br />
<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />